Canon imageRUNNER ADVANCE C350 series Service Manual page 766

Table of Contents

Advertisement

Location
Alarm
Description
Code
Code
10
0018 Toner (M) prior delivery
alarm
10
0019 Toner (C) prior delivery
alarm
10
0020 Toner (Bk) prior delivery
alarm
10
0022 Patch detection light
intensity abnormal change
alarm
10
0100 Toner bottle replacement
completion alarm
10
0201 Toner Container (Y) level
detection error
10
0202 Toner Container (M) level
detection error
10
0203 Toner Container (C) level
detection error
10
0204 Toner Container (Bk) level
detection error
11
0001 Waste Toner Container full
level
11
0010 Display of Waste Toner
Container preparation
warning
7
Error•Jam•Alarm > Alarm Code > Alarm Code
Details
An alarm for requesting a prior delivery is sent to
UGW as the value of Toner level detect value has
reached the value set in COPIER > OPTION > FNC-
SW > T-DLV-CL.
An alarm for requesting a prior delivery is sent to
UGW as the value of Toner level detect value has
reached the value set in COPIER > OPTION > FNC-
SW > T-DLV-CL.
An alarm for requesting a prior delivery is sent to
UGW as the value of Toner level detect value has
reached the value set in COPIER > OPTION > FNC-
SW > T-DLV-BK.
The replacement of the Toner Container was detected.
-
-
-
-
"Movement: A message ""The waste toner container
is full."" is displayed on the Control Panel, and the
machine is stopped.
Cause: The Waste Toner Counter reaches full.
Measures: Replace the Waste Toner Container."
"Movement: A message is displayed on the Control
Panel. (Continuous printing is enabled.)
Cause: Display of Waste Toner Box preparation
warning"
7
Error•Jam•Alarm > Alarm Code > Alarm Code
Location
Alarm
Description
Code
Code
30
0021 Tried to apply abnormally
great primary transfer
voltage at primary transfer
ATVC control for yellow.
30
0022 Tried to apply abnormally
great primary transfer
voltage at primary transfer
ATVC control for magenta.
30
0023 Tried to apply abnormally
great primary transfer
voltage at primary transfer
ATVC control for cyan.
Details
Error in the Primary Transfer High Voltage PCB, Error
in the Primary Transfer Roller (ITB Unit)
1. Check failure of the harness between the Primary
Transfer High Voltage PCB and the DC Controller
PCB (open circuit, trapped cable, connector
disconnection).
-> Replace the harness if it is faulty
2. Check connection failure between the Primary
Transfer High Voltage PCB and the Primary Transfer
Roller (Check that the connection is free from open
circuit or GND contact)
3. Replace the Primary Transfer High Voltage PCB
4. Replace the ITB Unit
5. Replace the DC Controller PCB
Error in the Primary Transfer High Voltage PCB, Error
in the Primary Transfer Roller (ITB Unit)
1. Check failure of the harness between the Primary
Transfer High Voltage PCB and the DC Controller
PCB (open circuit, trapped cable, connector
disconnection).
-> Replace the harness if it is faulty
2. Check connection failure between the Primary
Transfer High Voltage PCB and the Primary Transfer
Roller (Check that the connection is free from open
circuit or GND contact)
3. Replace the Primary Transfer High Voltage PCB
4. Replace the ITB Unit
5. Replace the DC Controller PCB
Error in the Primary Transfer High Voltage PCB, Error
in the Primary Transfer Roller (ITB Unit)
1. Check failure of the harness between the Primary
Transfer High Voltage PCB and the DC Controller
PCB (open circuit, trapped cable, connector
disconnection).
-> Replace the harness if it is faulty
2. Check connection failure between the Primary
Transfer High Voltage PCB and the Primary Transfer
Roller (Check that the connection is free from open
circuit or GND contact)
3. Replace the Primary Transfer High Voltage PCB
4. Replace the ITB Unit
5. Replace the DC Controller PCB