Canon imageRUNNER ADVANCE C350 series Service Manual page 883

Table of Contents

Advertisement

COPIER> FUNCTION> CLEAR
MN-CON
RAM clear of MNCON PCB SRAM Board
Lv.1 Details
To clear the area equivalent to the Main Controller PCB SRAM
Board.
All data in the area equivalent to the SRAM Board is initialized.
Use case
When clearing the area equivalent to the Main Controller PCB SRAM
Board
Adj/set/operate method 1) Select the item, and then press OK key.
The machine is automatically rebooted.
2) Turn OFF/ON the main power switch.
Caution
- Address Book, Forwarding Settings, Settings/Registration
(Preferences), Adjustment/Maintenance, Function Settings, Set
Destination, Management Settings, TPM Settings, etc. are deleted.
- Since the file management information is initialized, images on the
HDD cannot be read.
- Before execution of this item, be sure to output the service mode
setting values by P-PRINT/DCM. After execution, enter necessary
setting values.
- The RAM data is cleared after the main power switch is turned
OFF/ON.
- If this item is executed while a login application other than Default
Authentication is activated, any symptom occurs. (e.g. The login
screen is not displayed.) In this case, switch the login application to
Default Authentication once.
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
CARD
Clear of card ID-related data
Lv.1 Details
To clear the data related to the card ID (department).
Use case
When clearing the data related to the card ID
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
The value is cleared after the main power switch is turned OFF/ON.
ALARM
Clear of alarm code history
Lv.1 Details
To clear the alarm code log (COPIER> DISPLAY> ALARM-2,
ALARM-3).
Use case
When clearing the alarm code history
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
The alarm log is cleared after the main power switch is turned OFF/
ON.
Related service mode
COPIER> DISPLAY> ALARM-2, ALARM-3
8
Service Mode > COPIER > FUNCTION > CLEAR
8
Service Mode > COPIER > FUNCTION > CLEAR
COPIER> FUNCTION> CLEAR
CA-KEY
Init of key pair, certificate and CRL
Lv.2 Details
To simultaneously delete the key pair, certificate and CRL which are
additionally registered by the user, and return to the default state.
Use case
When a service person replaces/discards the device
Adj/set/operate method 1) Select the item, and then press OK key.
2) Check that OK is displayed.
3) Turn OFF/ON the main power switch.
Caution
- Unless this item is executed at the time of replacement/discard of
the device, the key pair, certificate and CRL which are additionally
registered by the user remain in the HDD, which is a problem in
terms of security.
- Do not execute this item carelessly because the key pair,certificate
and CRL which are additionally registered are deleted when
it is executed. If they are deleted mistakenly, they need to be
again registered by the user. If no CA certificate and key pair are
additionally registered, the machine condition becomes the same as
the one at the time of factory
- When NG is displayed in 2), there is a possibility that deletion was
not executed. In this case, surely execute the deletion by initializing
the HDD, etc.
Display/adj/set range
At normal termination: OK, At abnormal termination: NG
Supplement/memo
After this function is executed, the registered key pair, certificate and
CRL are initialized upon turning OFF and the ON the main power,
and the key pair, certificate and CRL registered at the time of factory
shipment are decompressed from the archive.
ERDS-DAT
Initialization of E-RDS SRAM data
Lv.1 Details
To initialize the SCM value of the Embedded-RDS stored in the
SRAM.
SCM values are ON/OFF of E-RDS, server's port number, server's
SOAP URL, and communication schedule with the server (how often
the data is acquired), etc.
The value set by COPIER> FUNCTION> INSTALL> E-RDS, RGW-
PORT, RGW-ADR, COM-LOG is cleared.
Use case
When upgrading the Bootable in the E-RDS environment
Adj/set/operate method Select the item, and then press OK key.
Caution
The method of using the SRAM in E-RDS differs depending on the
Bootable version. Therefore, unless the SRAM data is cleared at the
time of version upgrade, data inconsistency occurs.
Display/adj/set range
At normal termination: OK, At abnormal termination: NG
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, RGW-ADR,
COM-LOG
8-113