COPIER> DISPLAY> HT-C
SGNL-A-Y
Dspl ARCDAT screen A Y-patch current VL
Lv.2 Details
To display the current Y-patch value of screen A in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-A-M
Dspl ARCDAT screen A M-patch current VL
Lv.2 Details
To display the current M-patch value of screen A in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-A-C
Dspl ARCDAT screen A C-patch current VL
Lv.2 Details
To display the current C-patch value of screen A in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-A-K
Dspl ARCDAT screen A Bk-patch current VL
Lv.2 Details
To display the current Bk-patch value of screen A in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-B-Y
Dspl ARCDAT screen B Y-patch current VL
Lv.2 Details
To display the current Y-patch value of screen B in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-B-M
Dspl ARCDAT screen B M-patch current VL
Lv.2 Details
To display the current M-patch value of screen B in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
8
Service Mode > COPIER > DISPLAY > HT-C
8
Service Mode > COPIER > DISPLAY > HT-C
COPIER> DISPLAY> HT-C
SGNL-B-C
Dspl ARCDAT screen B C-patch current VL
Lv.2 Details
To display the current C-patch value of screen B in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-B-K
Dspl ARCDAT screen B Bk-patch current VL
Lv.2 Details
To display the current Bk-patch value of screen B in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-C-Y
Dspl ARCDAT screen C Y-patch current VL
Lv.2 Details
To display the current Y-patch value of screen C in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-C-M
Dspl ARCDAT screen C M-patch current VL
Lv.2 Details
To display the current M-patch value of screen C in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-C-K
Dspl ARCDAT screen C Bk-patch current VL
Lv.2 Details
To display the current Bk-patch value of screen C in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-C-C
Dspl ARCDAT screen C C-patch current VL
Lv.2 Details
To display the current C-patch value of screen C in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
8-44
8-44