Canon imageRUNNER ADVANCE C350 series Service Manual page 285

Table of Contents

Advertisement

2
Technical Explanation > DCM > DCM > Import/Export by Service Mode (External)
5. The names of DCM files saved in USB flash drive are displayed. Press [->].
6. Select [PASSWD], enter a password from the software keyboard, and then press [OK].
Click here
Note:
Limitations regarding the password
Character string of software keyboard: 0 to 32 characters
No password is set when 0 character is entered
No space is allowed in the middle of a password
Password is case sensitive
Limitations regarding the DCM file no password
DCM files exported without password can only be imported by service mode. They cannot
be imported by remote UI.
2
Technical Explanation > DCM > DCM > Import/Export by Service Mode (External)
7. After entering the password, select [BACKUP]. Press [OK] to execute export.
8. "OK!" is displayed in the status column when the processing is successfully completed.
Press [<-].
F-2-425
F-2-426
9. Select [LIST], enter "0" and press [OK]. Unmount the USB flash drive.
It can also be removed by pressing the Remove button on the main menu.
2-242
F-2-427
F-2-428
F-2-429
2-242