Canon imageRUNNER ADVANCE C350 series Service Manual page 908

Table of Contents

Advertisement

COPIER> OPTION> IMG-FIX
FXS-TMP5
Image leading edge control temp: thin
Lv.1 Details
To set the offset of image leading edge control temperature for thin
paper (60 to 63 g/m2).
As the value is incremented by 1, the control temperature is
increased by 5 deg C from the specified value.
Increase the value when a fixing failure occurs on the leading edge
of paper.
Decrease the value when uneven gloss occurs on the leading edge
(56.5 mm).
Use case
When uneven gloss occurs on the leading edge (56.5 mm) of thin
paper
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to change the value a little at a time. Otherwise, offset/image
failure occurs when setting an extreme value.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
FXS-TMP6
Image leading edge control temp:envelope
Lv.1 Details
To set the offset of image leading edge control temperature for
envelope.
As the value is incremented by 1, the control temperature is
increased by 5 deg C from the specified value.
Increase the value when a fixing failure occurs on the leading edge
of paper.
Decrease the value when uneven gloss occurs on the leading edge
(56.5 mm).
Use case
When uneven gloss occurs on the leading edge (56.5 mm) of
envelope
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to change the value a little at a time. Otherwise, offset/image
failure occurs when setting an extreme value.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
8
Service Mode > COPIER > OPTION > IMG-FIX
8
Service Mode > COPIER > OPTION > IMG-FIX
COPIER> OPTION> IMG-FIX
FXST2-N2
Set of ITOP wait time:Plain ppr in LL Ev
Lv.1 Details
To set initial rotation time when plain paper 1/2/3 is fed with a
temperature lower than 10 deg C.
Increase the value when a fixing failure occurs.
Use case
When a fixing failure occurs in an environment where temperature is
lower than 10 deg C
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
As the value is increased, (as the initial rotation time becomes
longer), FCOT is increased.
Display/adj/set range
0 to 20
Unit
1 second
Default value
0
FXST2-UH
Set of ITOP wait time:Heavy ppr in LL Ev
Lv.1 Details
To set initial rotation time when heavy paper 1/2/3 is fed with a
temperature lower than 10 deg C.
Increase the value when a fixing failure occurs.
Use case
When a fixing failure occurs in an environment where temperature is
lower than 10 deg C
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
As the value is increased, (as the initial rotation time becomes
longer), FCOT is increased.
Display/adj/set range
0 to 30
Unit
1 second
Default value
0
FLYING
ON/OFF of flying start temperature ctrl
Lv.2 Details
To set ON/OFF of flying start temperature control.
When "1" is set, the flying start temperature control is not executed.
This is more life-conscious for Fixing Assembly compared to "0".
Use case
When preferring to extend the life of Fixing Assembly. However,
setting of "1" does not mean that the life of Fixing Assembly is always
extended.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
When "1" is set, FCOT/FPOT is reduced.
Display/adj/set range
0 to 1
0: ON, 1: OFF
Default value
0
8-138