Canon imageRUNNER ADVANCE C350 series Service Manual page 862

Table of Contents

Advertisement

COPIER> ADJUST> HV-TR
2TR-R2-2
Sec trn ATVC ctrl ppr allot V:rcycl2 2nd
Lv.1 Details
To adjust the paper allotted voltage applied to the 2nd side of
recycled paper 2 at secondary transfer ATVC control.
When mottled image occurs, increase the value if it is due to
insufficient secondary transfer current and decrease the value if it is
due to overcurrent.
Use case
When adjusting the secondary transfer bias individually according to
paper type and 1st/2nd side
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
30 V
Default value
0
2TR-R3-1
Sec trn ATVC ctrl ppr allot V:rcycl3 1st
Lv.1 Details
To adjust the paper allotted voltage applied to the 1st side of recycled
paper 3 at secondary transfer ATVC control.
When mottled image occurs, increase the value if it is due to
insufficient secondary transfer current and decrease the value if it is
due to overcurrent.
Use case
When adjusting the secondary transfer bias individually according to
paper type and 1st/2nd side
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
30 V
Default value
0
2TR-R3-2
Sec trn ATVC ctrl ppr allot V:rcycl3 2nd
Lv.1 Details
To adjust the paper allotted voltage applied to the 2nd side of
recycled paper 3 at secondary transfer ATVC control.
When mottled image occurs, increase the value if it is due to
insufficient secondary transfer current and decrease the value if it is
due to overcurrent.
Use case
When adjusting the secondary transfer bias individually according to
paper type and 1st/2nd side
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
30 V
Default value
0
8
Service Mode > COPIER > ADJUST > HV-TR
8
Service Mode > COPIER > ADJUST > HV-TR
COPIER> ADJUST> HV-TR
2TR-H1-1
Sec trn ATVC ctrl ppr allot V: hvy1 1st
Lv.1 Details
To adjust the paper allotted voltage applied to the 1st side of heavy
paper 1 at secondary transfer ATVC control.
When mottled image occurs, increase the value if it is due to
insufficient secondary transfer current and decrease the value if it is
due to overcurrent.
Use case
When adjusting the secondary transfer bias individually according to
paper type and 1st/2nd side
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
30 V
Default value
0
2TR-H1-2
Sec trn ATVC ctrl ppr allot V: hvy1 2nd
Lv.1 Details
To adjust the paper allotted voltage applied to the 2nd side of heavy
paper 1 at secondary transfer ATVC control.
When mottled image occurs, increase the value if it is due to
insufficient secondary transfer current and decrease the value if it is
due to overcurrent.
Use case
When adjusting the secondary transfer bias individually according to
paper type and 1st/2nd side
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
30 V
Default value
0
2TR-H2-1
Sec trn ATVC ctrl ppr allot V: hvy2 1st
Lv.1 Details
To adjust the paper allotted voltage applied to the 1st side of heavy
paper 2 at secondary transfer ATVC control.
When mottled image occurs, increase the value if it is due to
insufficient secondary transfer current and decrease the value if it is
due to overcurrent.
Use case
When adjusting the secondary transfer bias individually according to
paper type and 1st/2nd side
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
30 V
Default value
0
8-92
8-92

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents