Error
Detail
Location
Item
code
Code
E196 0602 05
Title
EEPROM communication error
Detection
Although write polling to the RTC from the DC Controller PCB
description
(CPU) was performed for 3 times, no response was received
and timeout occurred.
Remedy
[Related parts]
- Harness between the DC Controller PCB (UN04/J110) and the
Y/M/C/Bk Laser Driver PCB (UN05/J202) (Unit of replacement:
CABLE, LASER SCANNER)
- Harness between the DC Controller PCB (UN04/J184)
and the Developing High-voltage PCB (UN06/J241) (Unit of
replacement: 2ND TRNSFR. H.V. PCB ASSEMBLY)
- Y/M/C/Bk Laser Driver PCB (UN05) (Unit of replacement:
LASER SCANNER ASSEMBLY)
- Developing High-voltage PCB (UN06) (Unit of replacement:
2ND TRNSFR. H.V. PCB ASSEMBLY)
- DC Controller PCB (UN04) (Unit of replacement: DC
CONTROLLER PCB ASSEMBLY)
[Points to note at work] When checking the harness/cable or
connector, perform the following work.
1. Disconnect and then connect the connector to check that
there is no bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.
[Reference] Before replacing the DC Controller PCB, back up
the service mode data (approx. 2 min) and restore the backup
data after the replacement so the data may be able to be
protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM>
DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM>
DSRAMRES
E196 060F 05
Title
EEPROM communication error
Detection
The number of read/write job data to the RTC (device
description
information) exceeded 100.
Remedy
[Remedy] Turn OFF and then ON the main power.
[Reference] Data (device information) is reset by turning OFF
and then ON the main power.
7
Error•Jam•Alarm > Error Code > Error Code Details
Description
7
Error•Jam•Alarm > Error Code > Error Code Details
Error
Detail
Location
Item
code
Code
E196 0800 05
Title
EEPROM communication error
Detection
The NACK (a negative reply sent by the reception side to the
description
sending side) was received for 3 times in communication from
the DC Controller PCB (CPU) to the HVT EEPROM.
Remedy
[Related parts]
- Harness between the DC Controller PCB (UN04/J110) and the
Y/M/C/Bk Laser Driver PCB (UN05/J202) (Unit of replacement:
CABLE, LASER SCANNER)
- Harness between the DC Controller PCB (UN04/J184)
and the Developing High-voltage PCB (UN06/J241) (Unit of
replacement: 2ND TRNSFR. H.V. PCB ASSEMBLY)
- Y/M/C/Bk Laser Driver PCB (UN05) (Unit of replacement:
LASER SCANNER ASSEMBLY)
- Developing High-voltage PCB (UN06) (Unit of replacement:
2ND TRNSFR. H.V. PCB ASSEMBLY)
- DC Controller PCB (UN04) (Unit of replacement: DC
CONTROLLER PCB ASSEMBLY)
[Points to note at work] When checking the harness/cable or
connector, perform the following work.
1. Disconnect and then connect the connector to check that
there is no bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.
[Reference] Before replacing the DC Controller PCB, back up
the service mode data (approx. 2 min) and restore the backup
data after the replacement so the data may be able to be
protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM>
DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM>
DSRAMRES
7-60
Description
7-60