Canon imageRUNNER ADVANCE C350 series Service Manual page 830

Table of Contents

Advertisement

COPIER> ADJUST> CCD
MTF-M1
MTF value 1 setting: horz scan [DADF]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Main Controller PCB/clearing the Reader-
related RAM data
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
MTF-M2
MTF value 2 setting: horz scan [DADF]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Main Controller PCB/clearing the Reader-
related RAM data
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
MTF-M3
MTF value 3 setting: horz scan [DADF]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Main Controller PCB/clearing the Reader-
related RAM data
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
8
Service Mode > COPIER > ADJUST > CCD
8
Service Mode > COPIER > ADJUST > CCD
COPIER> ADJUST> CCD
MTF-M4
MTF value 4 setting: horz scan [DADF]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Main Controller PCB/clearing the Reader-
related RAM data
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
MTF-M5
MTF value 5 setting: horz scan [DADF]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Main Controller PCB/clearing the Reader-
related RAM data
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
MTF-M6
MTF value 6 setting: horz scan [DADF]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Main Controller PCB/clearing the Reader-
related RAM data
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
8-60
8-60