COPIER> DISPLAY> HT-C
TGT-B-Y
Dspl ARCDAT screen B Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-B-M
Dspl ARCDAT screen B M-color target VL
Lv.2 Details
To display the M-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-B-C
Dspl ARCDAT screen B C-color target VL
Lv.2 Details
To display the C-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-B-K
Dspl of ARCDAT screen B Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-C-Y
Dspl ARCDAT screen C Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
8
Service Mode > COPIER > DISPLAY > HT-C
8
Service Mode > COPIER > DISPLAY > HT-C
COPIER> DISPLAY> HT-C
TGT-C-M
Dspl ARCDAT screen C M-color target VL
Lv.2 Details
To display the M-patch target value of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-C-C
Dspl ARCDAT screen C C-color target VL
Lv.2 Details
To display the C-patch target value of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-C-K
Dspl of ARCDAT screen C Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
SUM-A-Y
Dspl ARCDAT screen A Y-color ctrl differ
Lv.2 Details
To display Y-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-A-M
Dspl ARCDAT screen A M-color ctrl differ
Lv.2 Details
To display M-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023