Canon imageRUNNER ADVANCE C350 series Service Manual page 959

Table of Contents

Advertisement

COPIER> TEST> PG
COLOR-M
M-color output setting at test print
Lv.1 Details
To make a setting of M-color output for test print.
The setting is applied to all types.
When setting "COLOR-M" to 1 and other items to "0", a single
M-color is output.
Use case
At test print
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Not output, 1: Output
Default value
1
COLOR-C
C-color output setting at test print
Lv.1 Details
To make a setting of C-color output for test print.
The setting is applied to all types.
When setting "COLOR-C" to 1 and other items to "0", a single C-color
is output.
Use case
At test print
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Not output, 1: Output
Default value
1
COLOR-K
Bk-color output setting at test print
Lv.1 Details
To make a setting of Bk-color output for test print.
The setting is applied to all types.
When setting "COLOR-K" to 1 and other items to "0", a single Bk-
color is output.
Use case
At test print
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Not output, 1: Output
Default value
1
F/M-SW
Setting of PG full color/single color
Lv.1 Details
To set for the output in full color/monochrome color with PG.
Use case
When separating (identifying) the cause whether it's due to color or
monochrome.
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Full color, 1: Single color
Default value
0
8
Service Mode > COPIER > TEST > PG
8
Service Mode > COPIER > TEST > PG
COPIER> TEST> PG
PG-PICK
Setting of test print paper source
Lv.1 Details
To set the pickup cassette for test print output.
Use case
- At trouble analysis
- At test print output
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
1 to 8
1: Cassette1, 2: Cassette2, 3: Cassette3, 4: Cassette4, 5: Multi-
purpose Tray, 6 to 8: Not used
Default value
1
2-SIDE
Setting of PG 2-sided mode
Lv.1 Details
To set 1-sided/2-sided print for PG output.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: 1-sided, 1: 2-sided
Default value
0
PG-QTY
Setting of PG output quantity
Lv.1 Details
To set the number of sheets for PG output.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
1 to 999
Unit
1 sheet
Default value
1
8-189