2
Technical Explanation > MEAP > Maintenance > Procedures to Restore Backup Data
CAUTION:
Do not execute [Initialize All Data/Settings] in [Settings/Registration] during the period
from backup using SST to recovery of the data.
When [Initialize All Data/Settings] is executed, the key used to combine encrypted
backup data (SMS password, etc.) is initialized, which makes it impossible to combine
the data.
It means that SMS cannot be accessed even when the backup data has been
recovered using SST.
If you inadvertently executed [Initialize All Data/Settings] and can no longer access
SMS, the SMS login password needs to be initialized by following the procedure shown
in "When SMS Cannot Be Accessed" in "Login to SMS" in this manual.
2
Technical Explanation > MEAP > Maintenance > Procedures to Restore Backup Data
■ Procedures to Restore Backup Data
1) Connecting to the device
2) Restoring backup file
F-2-294
3) Transferring Data
4) Turn off and on the main power switch of the device to gain access in SMS to check that
5) Restore the backup data and setting saved. Note that the user information of the local
Connect the device using SST by following step 1 to step 4 of the Procedure for backing up
the MEAP application area using SST.
Click [Download Data] and select the data backed up in the previous step (Meapback.bin)
to click [Start Restoring Data]. Note that the data backed up in a different version cannot be
restored.
When the data is successfully transferred, click the [OK] shown on the screen. To continue
other jobs, click [Return to Menu].
MEAP applications are surely restored.
device is included in the backup data, thus does not need to be restored.
2-178
F-2-295
F-2-296
2-178