Canon imageRUNNER ADVANCE C350 series Service Manual page 805

Table of Contents

Advertisement

■ DPOT
COPIER> DISPLAY> DPOT
2TR-PPR
Dspl of sec trns ATVC ppr allotted voltg
Lv.2 Details
To display the paper allotted voltage set by the latest secondary
transfer ATVC control.
The appropriate range may be exceeded due to wrong media setting.
Use case
When transfer failure occurs on certain media
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 5000
Unit
1 V
2TR-BASE
Dspl of sec transfer ATVC base voltage
Lv.2 Details
To display the base voltage set by the latest secondary transfer
ATVC control.
The appropriate range may be exceeded due to wrong media setting.
Use case
When transfer failure occurs on certain media
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 6000
Unit
1 V
Appropriate target value 500 - 5000
1TR-DC-Y
Dspl of primary transfer voltage (Y)
Lv.2 Details
To display the voltage lastly applied to the Primary Transfer Roller (Y).
Use case
When transfer failure occurs due to the primary transfer
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 5000
Unit
1 V
Appropriate target value 50 - 2000
1TR-DC-M
Dspl of primary transfer voltage (M)
Lv.2 Details
To display the voltage lastly applied to the Primary Transfer Roller (M).
Use case
When transfer failure occurs due to the primary transfer
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 5000
Unit
1 V
Appropriate target value 50 - 2000
1TR-DC-C
Dspl of primary transfer voltage (C)
Lv.2 Details
To display the voltage lastly applied to the Primary Transfer Roller (C).
Use case
When transfer failure occurs due to the primary transfer
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 5000
Unit
1 V
Appropriate target value 50 - 2000
8
Service Mode > COPIER > DISPLAY > DPOT
8
Service Mode > COPIER > DISPLAY > DPOT
COPIER> DISPLAY> DPOT
1TR-DC-K
Dspl of primary transfer voltage (Bk)
Lv.2 Details
To display the voltage lastly applied to the Primary Transfer Roller
(Bk).
Use case
When transfer failure occurs due to the primary transfer
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 5000
Unit
1 V
Appropriate target value 50 - 2000
LPWR-Y
Display of laser power (Y)
Lv.2 Details
To display Y laser power determined by D-max control.
FF display with low image density is considered that the
Photosensitive Drum may be nearly the end of life.
Use case
When the image density is low
Adj/set/operate method N/A (Display only)
Display/adj/set range
00 - FF (hexadecimal)
Appropriate target value 60 - FF
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation> Full Adjust, Quick Adjust
LPWR-M
Display of laser power (M)
Lv.2 Details
To display M laser power determined by D-max control.
FF display with low image density is considered that the
Photosensitive Drum may be nearly the end of life.
Use case
When the image density is low
Adj/set/operate method N/A (Display only)
Display/adj/set range
00 - FF (hexadecimal)
Appropriate target value 60 - FF
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation> Full Adjust, Quick Adjust
LPWR-C
Display of laser power (C)
Lv.2 Details
To display C laser power determined by D-max control.
FF display with low image density is considered that the
Photosensitive Drum may be nearly the end of life.
Use case
When the image density is low
Adj/set/operate method N/A (Display only)
Display/adj/set range
00 - FF (hexadecimal)
Appropriate target value 60 - FF
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation> Full Adjust, Quick Adjust
8-35
8-35