Canon imageRUNNER ADVANCE C350 series Service Manual page 811

Table of Contents

Advertisement

COPIER> DISPLAY> MISC
TNRB-IDC
Display of C-color Toner Container ID
Lv.1 Details
To display the ID of C-color Toner Container that is installed to the
machine
Use case
When checking whether the barcode ID on the Toner Container is
read correctly
Adj/set/operate method N/A (Display only)
Display/adj/set range
12-digit decimal number
TNRB-IDK
Display of Bk-color Toner Container ID
Lv.1 Details
To display the ID of Bk-color Toner Container that is installed to the
machine
Use case
When checking whether the barcode ID on the Toner Container is
read correctly
Adj/set/operate method N/A (Display only)
Display/adj/set range
12-digit decimal number
ENV-1TR
Dspl of prmry trns ATVC ctrl environment
Lv.2 Details
To display the environment (relative humidity) at execution of the
primary transfer ATVC control.
Use case
When checking the environment where the primary transfer ATVC
control is executed
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 6
8
Service Mode > COPIER > DISPLAY > HT-C
T-8-11
8
Service Mode > COPIER > DISPLAY > HT-C
■ HT-C
COPIER> DISPLAY> HT-C
TGT-A-Y
Dspl ARCDAT screen A Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-A-M
Dspl ARCDAT screen A M-color target VL
Lv.2 Details
To display the M-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-A-C
Dspl ARCDAT screen A C-color target VL
Lv.2 Details
To display the C-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-A-K
Dspl of ARCDAT screen A Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700