Canon imageRUNNER ADVANCE C350 series Service Manual page 841

Table of Contents

Advertisement

■ DENS
COPIER> ADJUST> DENS
HLMT-PTY
Adj ATR Sensor (Y) dens crrct upr limit
Lv.2 Details
To adjust the upper limit of the target density correction (lower limit of
TD ratio) of the ATR Sensor (Y).
When the value is increased (TD ratio is decreased), fogging/
scattering is alleviated.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
HLMT-PTM
Adj ATR Sensor (M) dens crrct upr limit
Lv.2 Details
To adjust the upper limit of the target density correction (lower limit of
TD ratio) of the ATR Sensor (M).
As the value is incremented by 1, the lower limit of TD ratio is
decreased by 0.5 %.
When the value is increased, fogging/scattering is alleviated.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
8
Service Mode > COPIER > ADJUST > DENS
8
Service Mode > COPIER > ADJUST > DENS
COPIER> ADJUST> DENS
HLMT-PTC
Adj ATR Sensor (C) dens crrct upr limit
Lv.2 Details
To adjust the upper limit of the target density correction (lower limit of
TD ratio) of the ATR Sensor (C).
As the value is incremented by 1, the lower limit of TD ratio is
decreased by 0.5 %.
When the value is increased, fogging/scattering is alleviated.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
LLMT-PTY
Adj ATR Sensor (Y)dens crrct lowr limit
Lv.2 Details
To adjust the lower limit of the target density correction (upper limit of
TD ratio) of the ATR Sensor (Y).
As the value is decremented by 1, the lower limit of TD ratio is
increased by 0.5 %.
When the value is decreased, density is increased, but fogging/
scattering occurs.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
8-71
8-71