Technical Explanation > DCM > DCM > Export All by Remote UI
• Following limitations are applied to password for DCM file.
• Character string of software keyboard: 0 to 32 characters
• No password is set when 0 character is entered (The setting in which no password is
set is allowed only export by service mode)
• No space is allowed in the middle of a password
• Password is case sensitive
• At the time of following setting, host matchine does not recognize USB flash drive. The
DCM function is not usable, too.
[Settings/Registration] > [Preferences] > [External Interface] > [USB Settings] > [Use
MEAP Driver for External USB Device] = "On"
■ Limitations about Import/Export by Remote UI
• An import/export process ends with error while the following specific job is executed.
• Send job
• Forwarding job
• FAX reception job
• IFAX reception job
• If this function is executed with a print job simultaneously, it affects the operation such as;
UI is locked, or a print job is cleared by restart after import. So it requires careful operation.
• A device rejects an import/ export request during shutdown.
• If this function is executed with device information distribution or remote UI import/ export
(Individually) simultaneously, the first coming job takes priority and they are controlled
exclusively.
• If this function is executed with a firmware update by a CDS (Updater) simultaneously, a
firmware update process takes priority, and this function is stopped temporarily by restart.
• When error code is issued, this function ends with error.
• If the display language before import differs from that after import,, a setting value of a text
corrupts in some cases. The character corruption can be solved by changing the display
language to the appropriate one.
2
Technical Explanation > DCM > DCM > Export All by Remote UI
■ Export All by Remote UI
Changing the value of a related service mode item can include items of "Service Mode
Settings" in a DCM file that is to be exported by remote UI.
A DCM file exported by remote UI can also be imported by service mode without using
remote UI.
For details of import/export by remote UI, refer to the this machine's e-Manual.
Preparation
PC and web browser
USB flash drive to store the data of reference machine
Overall flow
1. Complete the device setting as a reference machine.
2. Change the setting value of the following service mode to [1] to display "Service Mode
Settings" on remote UI.
Service mode L1 > Copier > Option > USER > SMD-EXPT
• [0]: Hide the "Service Mode Settings" (Def.)
• [1]: Display the "Service Mode Settings"
3. Export including "Service Mode Settings" from remote UI.
4. Copy the DCM file to the root folder of the USB flash drive using a PC.
5. Connect the USB flash drive to the copy destination machine.
6. Execute import by specifying the target files from [RESTORE] in service mode. (Refer to
"Import Procedure" of "Import/Export by Service Mode (External)")
2-240
F-2-420
2-240