Canon imageRUNNER ADVANCE C350 series Service Manual page 893

Table of Contents

Advertisement

COPIER> OPTION> FNC-SW
FXWRNLVL
Set Fix Film life display threshold VL
Lv.2 Details
To set the threshold value to display the life of Fixing Film.
This item is enabled when the value at the following is set to "1"
(default: 0): COPIER> OPTION> DSPLY-SW> FXMSG-SW (ON/OFF
of Fixing Assembly replacement message)
The life judgment counter is stored in the DC Controller. It is not
possible to change or check the counter value.
Use case
When preventing the occurrence of fixing failure caused by the
continuous use of the Fixing Film beyond its life
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 3
0: Warning is hidden.
1: Warning is displayed when the life counter reaches the specified
value.
2. Warning is displayed when the print counter reaches the specified
value.
3: Warning is displayed when either the life counter or the print
counter reaches the specified value.
Default value
0
Related service mode
COPIER> OPTION> DSPLY-SW> FXMSG-SW
KSIZE-SW
Set of Chinese paper (K-size) support
Lv.2 Details
To set whether to detect/display the Chinese paper (K-size paper:
16K).
Use case
When using K-size paper
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Go through the following: COPIER> OPTION> FNC-SW> MODEL-
SZ; and if MODEL-SZ is "0: AB configuration", this mode is enabled.
Display/adj/set range
0 to 1
0: Not supported, 1: Supported
Default value
0
Related service mode
COPIER> OPTION> FNC-SW> MODEL-SZ
COPIER> OPTION> CST> CST-K-SW
Supplement/memo
16K paper: 270 x 195 mm
PDF-RDCT
PDF reduction set at forwarding
Lv.2 Details
To set whether to reduce the image for transmission when converting
the image received by IFAX into PDF for e-mail/file transmission.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Following the current setting, 1: Image reduction
Default value
0
8
Service Mode > COPIER > OPTION > FNC-SW
8
Service Mode > COPIER > OPTION > FNC-SW
COPIER> OPTION> FNC-SW
SJB-UNW
Reserve upper limit of secure print job
Lv.2 Details
To set the upper limit for the number of reserved jobs in secure print
job.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2
0: 50 jobs, 1: 90 jobs, 2: No limit
Default value
1
CARD-RNG
Card number setting (department number)
Lv.2 Details
To set the number of cards (departments) that can be used with the
Card Reader.
Use case
When setting the number of cards (departments)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 1000
Default value
1000
SJOB-CL
Set of scan job canceling by logout
Lv.1 Details
To set whether to cancel the scan job in operation by logout of the
user.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- The job in scanning operation cannot be canceled.
- Cancel by logout is kept in the log.
Display/adj/set range
0 to 1
0: Disabled, 1: Enabled
Default value
0
Supplement/memo
Scan job: A job after the scanning operation is completed.
USB-RCNT
Auto connect set at USB device disconnct
Lv.2 Details
To set to enable/disable automatic connection when the USB device
is disconnected.
With the setting to disable automatic connection, USB device cannot
be used if disconnecting and then connecting the USB device. To
enable connection again, the power needs to be turned OFF/ON.
With the setting to enable automatic connection, connect again after
disconnecting, and then connecting the USB device again.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
With the setting to enable automatic connection, disconnecting of 1
area makes automatic connection of all USB devices if there is USB
hub.
Display/adj/set range
0 to 1
0: No automatic connection, 1: Automatic connection
Default value
0