Canon imageRUNNER ADVANCE C350 series Service Manual page 973

Table of Contents

Advertisement

FEEDER
DISPLAY
FEEDER> DISPLAY
FEEDSIZE
Dspl of original size detected by DADF
Lv.1 Details
To display the original size detected by DADF.
Use case
At original size detection error
Display/adj/set range
0 to 999999
8
Service Mode > FEEDER > ADJUST
T-8-68
8
Service Mode > FEEDER > ADJUST
ADJUST
FEEDER> ADJUST
DOCST
Adj of DADF img lead edge margin:1-sided
Lv.1 Details
To adjust the margin at the leading edge of the image at DADF
1-sided reading.
As the value is incremented by 1, the margin at the leading edge
of the image is decreased by 0.1 mm. (The image moves in the
direction of the leading edge of the sheet.)
Execute this item when the output image after DADF installation is
displaced.
When replacing the Scanner Unit or Controller PCB/clearing the
Reader-related RAM data, enter the value of service label.
Use case
- When installing DADF
- When replacing the Scanner Unit
- When clearing the Reader-related RAM data
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Caution
Be sure to use DOCSTDUP for the front side at the time of 2-sided
reading.
Display/adj/set range
-30 to 30
Unit
0.1 mm
Default value
0
Related service mode
FEEDER> ADJUST> DOCSTDUP
Supplement/memo
Since the front side reading operation differs between 1-sided and
2-sided reading, separate service modes have been prepared to
improve the accuracy.
LA-SPEED
Fine adj of DADF image magnifictn: front
Lv.1 Details
To make a fine adjustment of the image magnification ratio in vertical
scanning direction at DADF reading.
As the value is incremented by 1, the image is reduced by 0.01% in
vertical scanning direction. (The feeding speed increases, and the
image is reduced.)
When replacing the Scanner Unit or Main Controller PCB/clearing
the Reader-related RAM data, enter the value of service label.
Use case
- When installing DADF
- When replacing the Scanner Unit
- When clearing the Reader-related RAM data
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-200 to 200
Unit
0.01 %
Default value
0