Technical Explanation > MEAP > Maintenance > Option for exclusive individual measure
Terms & Acronyms
SMS
The web-base service to provide user interfaces for application life cycle
(Service Management
management.
Service)
Socket
A virtual interface of an application for network communication. A user
only needs to specify a socket as a unit of an address and a port from an
application. This establishes the network connection for data transmission,
eliminating complication related to detailed communication procedures.
SSO-H (Single Sign-
Login service providing features of both local device authentication and
On H)
domain authentication. The former is the method that device independently
authorizes users; whereas the latter is that device links to the domain
controller on the network in the Active Directory environment to authorize
users.
Thread
A unit for program execution. A multi-task system allowing multiple
programs to run concurrently assigns a memory space and other resources
independently to each program, providing users with a feel as if only a
program is running. At least one thread is generated upon a program
generated.
URL
The method to denote Web page locations on Internet and the like. For
(Uniform Resource
instance, a URL on the Web is denoted as [http://www.w3.org/default. html].
Locator)
[http] at the beginning means that an address following this is in a web page
on the Internet.
USB
Abbreviation of Universal Serial Bus. This is the interface standard to link
between information devices.
USB system driver
The general-purpose driver that control the behavior of the device, there are
HID class driver, Mass Storage class driver and so on.
2
Technical Explanation > MEAP > Maintenance > Option for exclusive individual measure
Definitions and Explanations
■ Option for exclusive individual measure
● Display Setting of Copy Icon (level2)
Make a setting as to whether to display/hide the copy screen (copy tab) on the control panel.
This is the specification for users who want to customize hiding it on control panel.
Default value
1: display
Setting range, item
0: hide 1: display
Setting Procedure
1) Start [SERVICE MODE] in Level 1.
2) Press [COPIER] > [Option] > [DSPLY-SW].
T-2-86
3) Press [UI-COPY].