Canon imageRUNNER ADVANCE C350 series Service Manual page 802

Table of Contents

Advertisement

COPIER> DISPLAY> ACC-STS
MN-RAM
Display of MNCON PCB memory capacity
Lv.1 Details
To display the memory capacity of the Main Controller PCB.
Use case
When checking the memory capacity of the Main Controller PCB
Display/adj/set range
1024 (Fixed)
8
Service Mode > COPIER > DISPLAY > ANALOG
T-8-5
8
Service Mode > COPIER > DISPLAY > ANALOG
■ ANALOG
COPIER> DISPLAY> ANALOG
TEMP
Display of outside temperature
Lv.1 Details
To display the temperature outside the machine.
This is measured by the Environment Sensor 2 that detects the
outside air.
Use case
When checking the temperature outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 60
Unit
1 deg C
Appropriate target value 20 - 27
HUM
Display of outside humidity
Lv.1 Details
To display the humidity outside the machine.
This is measured by the Environment Sensor 2 that detects the
outside air.
Use case
When checking the humidity outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
5 to 90
Unit
1 %
Appropriate target value 30 - 70
ABS-HUM
Display of outside moisture amount
Lv.1 Details
To display the absolute moisture amount outside the machine.
This is measured by the Environment Sensor 2 that detects the
outside air.
Use case
When checking the moisture amount outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
1 g
Appropriate target value 0 - 22
FIX-E
Dspl of Fixing Main Heater temperature
Lv.1 Details
To display the temperature of the Fixing Main Heater detected by the
Main Thermistor 1.
Use case
When checking the temperature of Fixing Main Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
FIX-E2
Dspl Fixing Sub Heater front edge temp
Lv.1 Details
To display the front edge temperature of the Fixing Sub Heater
detected by the Sub Thermistor 1.
Use case
When checking the edge temperature of the Fixing Sub Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
8-32
8-32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents