2
Technical Explanation > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
4) Start [Service Mode] at Level 1.
5) Select [COPIER] > [Function] > [INSTALL] > [E-RDS].
6) Press the numeric key [1] on the control panel (the setting value is changed to 1) and touch
the [OK] button. (The data is reflected to the setting value field.)
NOTE:
This operation enables the communication function with UGW.
2
Technical Explanation > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
CAUTION:
The following settings i.e. RGW-PORT and RGW-ADR in Service mode must not be
change unless there are specific instructions to do so.
Changing these values will cause error in communication with UGW.
F-2-363
7) Select [COM-TEST] and then touch [OK].
NOTE:
This initiates the communication test between the device and the UGW.
F-2-364
2-208
F-2-365