COPIER> OPTION> FNC-SW
DMAX-DAY
Set D-max control execution frequency
Lv.1 Details
To set the frequency of D-max control that is executed after a
specified number of sheets is fed.
When 0 is set, the execution frequency of D-max control is
decreased by half.
Use case
When density varies at the time of making a large number of outputs
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Half, 1: Normal
Default value
1
UA-OFFSW
ON/OFF of unified auth function
Lv.1 Details
To set ON/OFF of the Unified Authentication function.
Set the value to 0 when not preferring to use the Unified
Authentication function because of security concern.
Use case
Upon user's request (not to use the Unified Authentication function)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: ON, 1: OFF
Default value
0
Supplement/memo
Unified Authentication: A function with which it is considered that
login authentication under it is performed by logging in it using
SSO-H.
MIB-NVTA
RFC-compatible character stringMIB write
Lv.1 Details
As default, MIB object which NVT-ASCII can be written exists in
order to link with LUI entry value. This violates RFC order, so a
problem like garbled 2-byte characters may occur in the SNMP
monitoring system, such as the 3rd vendor's MPS.
Whether non-RFC-compatible character strings are written in MIB
can be set using this mode.
When 1 is set, only the character strings which are strictly compatible
with RFC are written. (Writing operation is executed from the SNMP
manager.) LUI is not linked.
Use case
Upon user's request (operation with RFC-compatible system)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 3
0: Compatible in a conventional manner, 1: RFC-compatible, 2 to 3:
Not used
Default value
0
Supplement/memo
RFC: Document of Internet-related technical standards
NVT-ASCII: Network Virtual Terminal-ASCII
8
Service Mode > COPIER > OPTION > FNC-SW
8
Service Mode > COPIER > OPTION > FNC-SW
COPIER> OPTION> FNC-SW
SVC-RUI
Enabling of RUI function for servicing
Lv.1 Details
To set whether to enable the RUI function for servicing (not provided
to end users).
When 0 is set, the RUI function is disabled.
When setting the value other than 0, RUI function is enabled. The
value entered becomes password to use the RUI function.
Use case
When preferring to use the import function of background image file
of main menu
Adj/set/operate method Enter the setting value (other then 0), and then press OK key.
Display/adj/set range
0 to 65535
Default value
0
LCDSFLG
Enabling of local CDS server
Lv.1 Details
To set whether to use the local CDS server.
When CDSFIRM is 1, this setting is enabled. When this setting is
enabled, the [Setting] screen is displayed Settings/Registration>
Management Settings> License/Other> Register/Update Software>
Software Management Setting.
Use case
When using the local CDS server
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
This mode is enabled only when 1 is selected in COPIER> OPTION>
FNC-SW> CDS-FIRM.
Display/adj/set range
0 to 1
0: Disabled, 1: Enabled
Default value
0
Related service mode
COPIER> OPTION> FNC-SW> CDS-FIRM
Related UI menu
Management Settings> License/Other> Register/Update Software>
Software Management Setting> Setting
Supplement/memo
When local CDS is used, iW EMC/MC device firmware update plug-
in is required.
NO-LGOUT
Display/hide of logout button
Lv.1 Details
To set whether to display or hide [Logout] button.
When 0 is set, [Logout] button is displayed on the screen, and logout
with the ID key is enabled. (Normal)
When 1 is set, [Logout] button is not displayed, and logout with the
ID key is disabled.
Use case
Upon user's request (for customization, etc.)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Display, 1: Hide
Default value
0