7.10 Program Error (Pxxx)

(The bold characters are the message displayed on the screen.)
These alarms occur during automatic operation‚ and the causes of these alarms are mainly program
errors which occur‚ for instance‚ when mistakes have been made in the preparation of the machining
programs or when programs which conform to the specification have not been prepared.
Error No.
P 10
P 11
P 20
P 30
P 31
P 32
P 33
P 34
P 35
P 36
P 37
P 39
Downloaded from
ManualsNet.com
Details
EXCS. AXIS. No.
The number of axis addresses
commanded in the same block exceeds
the specifications.
AXIS ADR. ERROR
The axis address commanded by the
program and the axis address set by the
parameter do not match.
DIVISION ERROR
An axis command which cannot be
divided by the command unit has been
issued.
PARITY H
The number of holes per character on the
paper tape is odd.
PARITY V
The number of characters per block on
the paper tape is odd.
ADDRESS. ERROR
An address not listed in the specifications
has been used.
FORMAT ERROR
The command format in the program is
not correct.
G-CODE ERROR
A G code not listed in the specifications
has been used.
CMD-VALUE OVER
The setting range for the addresses has
been exceeded.
PROGRAM END ERR
"EOR" has been read during tape and
memory operation.
PROG. No. ZERO
A zero has been specified for program
and sequence numbers.
NO SPEC ERR
A non-specified G code was specified.
search engine
7. List of Alarms
7.10 Program Error
• Divide the alarm block command into two.
• Check the specifications.
• Revise the axis names in the program.
• Review the program.
• Check the paper tape.
• Check the tape puncher and tape reader.
• Make the number of characters per block
on the paper tape even.
• Set the parameter parity V selection off.
• Check and revise the program address.
• Check the specifications.
• Review the program.
• Check and correct the G code address in
the program.
• Review the program.
• Enter the M02 and M30 command at the
end of the program.
• Enter the M99 command at the end of the
subprogram.
• The program numbers are designated
across a range from 1 to 99999999.
• The sequence numbers are designated
across a range from 1 to 99999.
• Check the specifications.
IV - 71
Remedy

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents