2) Protection of user parameters and common variables (KEY 2)
3) Protection of machining program (KEY 3)
Downloaded from
ManualsNet.com
When KEY 2 is turned off, the operation items listed in Table 2 are inhibited.
No.
1
Machining parameter setting
2
Control parameter on/off
3
Axis parameter setting
4
Barrier data
5
Common variable setting
6
I/O basic parameter setting
7
MR-J2-CT parameter
8
Parameter tape input
9
Parameter tape output
(Note) When KEY 2 is off, pressing any key other than the MENU key on the screens
corresponding to numbers 1 to 7 in Table 2 does not enter any data, but displays
message "DATA PROTECT".
When an attempt is made to perform the operation of number 8 or 9, pressing the INPUT
key cannot input or output any data, causing message "DATA or PROTECT" to be
displayed.
When KEY 3 is turned off, the operation items listed in Table 3 are inhibited.
No.
1
Storing MDI data in memory
2
Editing machining program
3
Creating machining program
4
Setting comments of stored program
5
Storing and checking machining program in
memory
6
Erasing machining program (single, group, all)
7
Setting comment of stored program
8
Copying, condensing, and merging a machining
program, and changing its number
9
Outputting machining program
10
Modifying the buffer of machining program
(Note) When KEY 3 is off, pressing any key other than the MENU key on the screens
corresponding to numbers 1 to 4 and 6 to 8 in the above table or the extended operation
menu screen causes message "DATA PROTECT" to be displayed; no data can be input.
When an attempt is made to perform the operation of number 5, 9, or 10 in Table 3,
pressing the INPUT key (for 5 and 9) or the cursor key (for 10) causes message "DATA
PROTECT" to be displayed without the operation coming into effect.
search engine
5. Data Protection
5.1 Data Protection Key
Table 2 Data protection by KEY 2
Operation
Table 3 Data protection by KEY 3
Operation
IV - 17
Screen
PARAM/PROCESS
PARAM/CONTROL
PARAM/AXIS
PARAM/Barrier data
MONITOR/COMMON VARIABLE
IN/OUT (PARAMETER)
DIAGN AUX-PRM
IN/OUT/INPUT
IN/OUT/OUTPUT
Extended
Screen
operation menu
MDI
MDI ENTRY
EDIT
EDIT
PROGRAM
EDIT
IN/OUT/INPUT
IN/OUT/ERASE
IN/OUT/FILE
IN/OUT/COPY
IN/OUT/OUTPUT
MONITOR/
COORDINATE
FILE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents