3. Screen Operation When Using a Panel Computer
3.7 Realtime Wave Screen (For only the panel computer)
Press TIME/Div menu to display the
setting screen.
Set "100" as TIME/DIV value.
Press Trigger menu to display the
setting screen.
Set as follows;
TriggerCh: "CH1"
TriggerMode: "Repeat"
TriggerType: "X device"
TriggerLevel: "0x13"
TriggerEdge: "Off->On"
PreTrigger: "500"
StopType: "X device"
StopLevel: "0x13"
StopEdge: "On->Off"
Press START button to start sampling.
Waveform display starts at the time
when X device 0x13 is turned ON.
Waveform display stops when:
•X device 0x13 is turned OFF.
•START button is pressed again.
•30 seconds have passed since
waveform display started.