Mitsubishi Electric MELDAS C6 Instruction Manual page 307

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

Menu
Trigger
Downloaded from
ManualsNet.com
3. Screen Operation When Using a Panel Computer
3.7 Realtime Wave Screen (For only the panel computer)
TriggerCh.
(CH1/CH2)
Trigger Mode
(single/repeat/free-run)
Trigger Type
(Level/X device/
Y device/Alarm)
Trigger Level
(Level: 0 to 99999
X,Y device: 0 to FF
Alarm: None)
Trigger Edge
(Off→On/On→Off/Both
edge)
Pre Trigger
(0 to 9999ms)
Stop Type
(X device/Y device
/Alarm/None)
Stop Device
(X,Y device: 0 to FF
Alarm: None)
Stop Edge
(Off→On/On→Off/
Both edge)
search engine
Details
Designate the channel to set a trigger.
Designate the trigger mode.
"Single" means one-shot trigger.
"Repeat" starts next sampling when the trigger condition is
satisfied again after the previous data sampling finishes.
Select one from the followings.
Single
Repeat
FreeRun
Select the trigger type.
Selecting "Level" sets a trigger when the data exceed the given
value.
Selecting "X device" or "Y device" sets a trigger when X or Y
device turns.
The condition to turn to 0 or 1 depends on the edge setting.
When "Alarm" is selected, sampling stops when the servo alarm
or the spindle alarm occurs. Select from menu.
Level
Xdevice
Ydevice
Alarm
When "Level" is selected on "Trigger Type" above, set the
trigger level.
At this time, current setting value is displayed on the waveform
display area.
When "X device" or "Y device" is selected, set the device
address.
Change the setting by ▼ and ▲ buttons.
To select a digit to set, use ◄ and ► buttons.
Select the edge to set a trigger on.
Select from menu and set.
Both
Off→On
On→Off
edge
Set the pre-trigger value.
Change the setting by ▼ and ▲ buttons.
To select a digit to set, use ◄ and ► buttons.
Select the stop type.
When X or Y device is selected, sampling stops when X or Y
device turns.
The condition to turn to 0 or 1 depends on the edge setting.
When "Alarm" is selected, sampling stops when the servo alarm
or the spindle alarm occurs. Select from menu.
Xdevice
Ydevice
Alarm
None
Set the address of X or Y device when "X device" or "Y device"
is selected on "Stop Type".
Change the setting by ▼ and ▲ buttons.
To select a digit to set, use ◄ and ► buttons.
Set the turning edge of X or Y device when "X device" or "Y
device" is selected on "Stop Type". Select from menu and set.
Both
Off→On
On→Off
edge
I - 292

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents