Stored Stroke Limit Ib; Stored Stroke Limit Ic - Mitsubishi Electric MELDAS C6 Instruction Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

6.3 Stored Stroke Limit IB

The boundary is set for each axis with the parameters (axis parameters "#2061 OT_1B-" and "#2062
OT_1B+"). The inside of the set boundary is the prohibited range.

6.4 Stored Stroke Limit IC

The boundary is set for each axis with the parameters (axis parameters "#2061 OT_1B-" and "#2062
OT_1B+"). The inside of the set boundary is the machine moveable range.
This is valid when the axis parameter #2063 is set to 2, and cannot be used with soft limit IB.
Downloaded from
ManualsNet.com
Point 3
Range prohibited
with stored stroke
limit II B
Point 4
Point 2
Basic machine coordinate system
Machine moveable range
Point 2
Point 4
search engine
6. Stored Stroke Limit
6.3 Stored Stroke Limit IB
Point 1
Point 5
Point 6
Basic
machine
coordinate
system
Machine
moveable range
- setting value
+ setting value
Point 1
Additional movement
range
III - 41
The following values are set
with the coordinate values in the
basic machine coordinate
system.
Point 3 : #2062 OT_1B+
Point 4 : #2061 OT_1B–
The area determined by points
1 and 2 is the prohibited range
set with stored stroke limit I, and
the area determined by points 3
and 4 is the prohibited range set
with stored stroke limit II.
The following values are set
with the coordinate values in the
basic machine coordinate
system.
Point 3 : #2062 OT_1B+
Point 4 : #2061 OT_1B–
The area determined by points
1 and 2 is the prohibited range
Point 3
set with stored stroke limit I.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t