(Refer to "2.3 (I) Tool Offset
(L system)" for L system.

2.3.1.4 Manual Tool Length Measurement

By moving a tool manually from the reference to measurement point, the travel distance from the
reference to measurement point can be measured and set as tool offset.
(1) Tool length measurement I
(2) Tool length measurement II
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
When the tool is placed in the reference point, the distance from the tool tip to measurement
point (work top end) can be measured and set as tool offset data.
When the tool is placed in the reference point, the distance from the reference point to tool tip
can be measured and set as tool offset data.
search engine
2.3 (II). Tool Offset (M system)
I - 80
When TLM reference length
(#1102 tlm) = 0 and SURFACE
#0 = 0 are set, tool length
measurement I mode is set.