Mitsubishi Electric MELDAS C6 Instruction Manual page 83

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

(Refer to "2.3 (II). Tool Offset
(M system)" for M system.
(2) Page 2 is used to set and display a group's life management information.
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
2) Erasing all registered data of a group
All registered data (including the group No.) of a group can be erased by pressing
CAN
INPUT
+
.
C.B
(Note) The (MIN) display following "LIFE" or "USED" will change according the method
setting.
FORM 0: Time (MIN): Indicates that the data is displayed in minute units.
1: Count(SET): Indicates that the data is displayed in count units.
1) Selecting a display group
Select the group by setting # ( G) DATA (group No.).
When the group No. is set, the tool life management information of the tools registered in
that group will appear from #1 to #16. A highlighted # No. indicates that tool is a life-reached
tool (or a skip tool).
To display another group, set # ( G) DATA (group No.) again.
2) Registering a group
Register a group by setting # ( G) DATA (group No. to be registered) (FORM) (LIFE).
• Designate a group No. from 1 to 9999.
• Set FORM with for group life management by either time or count.
0: Time
If the FORM setting is omitted, the method becomes "0" (time).
• Set LIFE with the service life setting value for that group's tools. (0 to 999999).
If the LIFE setting is omitted, the life setting value becomes "0".
(Note 1)
The FORM and LIFE setting values can only be changed for a group being
displayed. This is to prevent mistaken settings. The setting is made with # ( G)
DATA (
(Only FORM and LIFE setting values can be changed.)
FORM and LIFE data is common data within that group. To suppress the LIFE
(Note 2)
value of a specific tool, adjust by setting the offset value for the USED data. In
this case, ST will be set to 1 (current tool), and the following new tool selection
signal will not be output at tool selection.
(Note 3)
The USED data will be incremented when the LIFE data is 0, but no judgment
will be made when the service life count is reached.
search engine
2.3 (I). Tool Offset (L system)
TOOL LIFE screen
Page 2
1: Count
) (FORM) (LIFE).