Mitsubishi Electric MELDAS C6 Instruction Manual page 96

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

(Refer to "2.3 (I) Tool Offset
(L system)" for L system.
(3) Tool offset data setting by tool length measurement
Position the tool to the reference point by
making return to reference point, etc.
Select a measurement tool.
Set the absolute value setting mode.
Turn on the machine operation board
TLM switch.
Move the tool to the measurement point
by making jog feed or manual handle
feed.
Upon completion of measurement,
specify the tool offset number.
(Note) For operation procedure, also refer to "Chapter III Machine Operation".
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
1) Tool length measurement I
START
search engine
2.3 (II). Tool Offset (M system)
Setting and display on the TOOL OFFSET
screen
Select the TOOL OFFSET screen.
Enter
O
key. "#A: ABS" is displayed in reverse video.
To message "TLM" is displayed on the TOOL
OFFSET screen.
0 is displayed in DATA (
The measurement value is displayed in DATA
(
) field in sequence.
The measurement value is also displayed at
[TLM].
The current value of the measurement axis is
displayed at [MACHINE].
Set the offset number in # (
INPUT
The measurement data is displayed at the
position of the specified offset number.
I - 81
in # (
), then press the
) field.
) and press the
key.
INPUT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents