(1) Stored stroke limit II (When prohibited range is on outside)
When used with the stored stroke limit I function, the confined range designated by the two
functions becomes the moveable range.
(2) Stored stroke limit IIB (When prohibited range is on inside)
A range except for that of the stored stroke limit I becomes the movement prohibited range.
Point 2
Downloaded from
ManualsNet.com
6.2 Stored Stroke Limit II
Basic machine
Range prohibited
coordinate system
with stored
stroke limit II
Machine moveable
range
Point 4
Point 2
- setting value
Point 3
Basic machine
Range prohibited
coordinate system
with stored stroke
limit II B
Machine
moveable range
Point 4
- setting value
+ setting value
search engine
6. Stored Stroke Limit
Point 1
Point 3
+ setting
value
Point 1
III - 40
The following values are set
with the coordinate values in the
basic machine coordinate
system.
Point 3 and 4:
#8205
OT-CHECK-P
#8204
OT-CHECK-N
The area determined by points
1 and 2 is the prohibited range
set with stored stroke limit I.