Mitsubishi Electric MELDAS C6 Instruction Manual page 118

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
8204 OT-CHECK-N
8205 OT-CHECK-P
8206 TOOL CHG. P
8207 G76/87 IGNR
(For M system only)
8208 G76/87 (-)
(For M system only)
8209 G60 SHIFT
(For M system only)
8210 OT INSIDE
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
Items
This sets the coordinates of the (–) direction in the
moveable range of the stored stroke limit II or the
lower limit coordinates of the prohibited range of
stored stroke limit IIB.
If the sign and value are the same as #8205, the
stored stroke limit II (or IIB) will be invalid.
If the stored stroke limit IIB function is selected, the
prohibited range will be between two points even
when #8204 and #8205 are set in reverse.
When II is selected, the entire range will be
prohibited.
This sets the coordinates of the (+) direction in the
moveable range of the stored stroke limit II or the
upper limit coordinates of the prohibited range of
stored stroke limit IIB.
Set the coordinates of the tool change position for
G30.n (tool change position return).
Set with coordinates in the basic machine
coordinate system.
Select the shift operation at G76 (fine boring) and
G87 (back boring)
Specifies the shift direction at G76 and G87.
Set the final positioning direction and distance per
axis for the G60 (uni-directional positioning
command).
The stored stoke limit function to be set in #8204
and #8205 prevents the machine from moving to
the inside or outside of the specified range.
0: Inhibits outside area. ( stored stroke limit
1: Inhibits inside area. ( stored stroke limit
search engine
2.4 Parameters
Details
II selected.)
IIB selected.)
I - 103
Setting range (unit)
-99999.999 to
+99999.999 (mm)
-99999.999 to
+99999.999 (mm)
-99999.999 to
+99999.999 (mm)
0 : Shift effective
1 : No shift
0 : Shift to (+)
direction
1 : Shift to (-)
direction
-99999.999 to
+99999.999 (mm)
0/1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents