6.1 Stored Stroke Limit I

This is a stroke limit function used by the machine maker. The boundary is set with the parameters
(axis specification parameters "#2013 OT–" and "#2014 OT+"). The outside of the set boundary is the
prohibited range.
When used with the stored stroke limit II function, the confined range designated by the two functions
becomes the movement valid range.
(Note1) This function will be invalid if the same value excluding "0" is set to the parameters
(Note2) When using indexing axis for C64T, inside of the specified range will be prohibited if the
Downloaded from
ManualsNet.com
Basic machine coordinates system
Machine movement valid range
Point 2
- setting value
"#2013 OT-" and "#2014 OT+".
"#2013 OT-" value is larger than that of "#2014 OT+".
search engine
6. Stored Stroke Limit
6.1 Stored Stroke Limit I
Point 1
+ setting
value
III - 38
The following values are set
with the coordinate values in
the basic machine
coordinate system.
Point 1: #2014 OT+
Point 2: #2013 OT–