Error No.
0112
0115
0117
0120
0121
0124
0160
1005
1106
Downloaded from
ManualsNet.com
7.1 Operation Alarms (Mxxx)
Details
Program Check Mode
The automatic start button was pressed
during program check or in program
check mode.
RESETTING
The automatic start pushbutton was
pressed during resetting or tape
rewinding.
PLAYBACK NOT POSSIBLE
The playback switch was turned on
during editing.
Synchronization correction mode ON
The synchronous correction mode
switch was pressed in a mode other
than handle or manual feed mode.
No synchronous control option
The synchronous control system
(register R932) was set with no
synchronous control option.
Simultaneous axis movement prohibited
during inclined axis control valid
The basic axis corresponding to the
inclined axis was started simultaneously
in the manual mode while the inclined
axis control was valid.
Axis with no maximum speed set for the
outside of the soft limit range
Returned from the outside of the soft
limit range for the axis with no maximum
speed set for the outside of the soft limit
range.
G114.* was executed during G114.*
Spindle synchronous phase calculation
illegal
The spindle synchronization phase
alignment command was issued while
the spindle synchronization phase
calculation request signal was ON.
search engine
7. List of Alarms
• Press the reset button to cancel the
program check mode.
• When rewinding the tape‚ wait for the
winding to end‚ or press the reset
button to stop the winding‚ and then
press the automatic start button.
• During resetting‚ wait for resetting to
end‚ and then press the automatic
start pushbutton.
• During editing‚ cancel the function by
pressing the input or previous screen
key‚ and then turn on the playback
switch.
• Select the handle or manual feed
mode.
• Turn off the correction mode switch.
• Set 0 in register R932.
• Turn the inclined axis and basic axis
start OFF for both axes. (This also
applied for manual/automatic
simultaneous start.)
• Invalidate the basic axis
compensation, or command one axis
at a time.
• Set the maximum speed for the outside
of the soft limit range.
• Change the soft limit range.
• Cancel with G113.
• Cancel with the spindle synchronization
cancel signal (SPSYC).
• Check the program.
• Check the sequence program.