7.9.3 Dialog Error Messages on Input/Output Screen

The following error messages will appear if an illegal operation is carried out on the Data I/O screen.
Operations can be continued by pressing the "OK" button.
The error messages are listed below.
Function
Copy
Delete
Downloaded from
ManualsNet.com
7.9 Operation Messages on Setting Display Unit
Target
Error message
NC
NC SYSTEM NO. ILLEGAL
DESIGNATED FILE NAME ALREADY EXIST
DIRECTRY ERROR
FILE NOT FOUND
FILE NAME FORMAT ILLEGAL
CAN'T READ OUT FILE
CAN'T WRITE FILE
UNABLE TO COPY : PROGRAM RUNNING
UNABLE TO COPY : PLC RUNNING
SOME ERROR FOUND IN FILE SYSTEM
NO. OF REGISTRATION OVER
OUT OF MEMORY
DATA PROTECT
FILE NAME TOO LONG
Can't write file because other data in/out
function is accessing this NC. Please try again
later.
Memory
DESIGNATED FILE NAME ALREADY EXIST
card
DIRECTRY ERROR
FILE NOT FOUND
CAN'T OPEN FILE
CAN'T CREATE FILE
TRANSFER ERROR : SOURCE FILE
TRANSFER ERROR : DESTINATION FILE
DRIVE NOT EXIST
Can't read out file because other data in/out
function is accessing this NC. Please try again
later.
NC
CAN'T DELETE FILE
DIRECTRY ERROR
FILE NOT FOUND
FILE NAME FORMAT ILLEGAL
UNABLE TO DELETE : PROGRAM RUNNING The file cannot be deleted. (The file is running.)
FILE-SYSTEM ERROR. PLEASE DO SETUP
PROCESS
DATA PROTECT
UNABLE TO DELETE : PLC RUNNING
Can't write file because other data in/out
function is accessing this NC. Please try again
later.
Memory
CAN'T DELETE FILE
card
DIRECTRY ERROR
FILE NOT FOUND
DRIVE NOT EXIST
DIRECTRY ERROR
FILE NOT FOUND
CAN'T OPEN FILE
TRANSFER ERROR : SOURCE FILE
DRIVE NOT EXIST
search engine
7. List of Alarms
The NC No. Mxx's xx is not within the designated range.
The copy destination file already exists.
The copy destination and copy source directories were not
found.
The copy source file was not found.
The file name format is illegal.
(The extension is wrong, etc.)
The copy source file cannot be read.
The copy destination file cannot be written.
Automatic starting, MDI execution or history file sampling is
in progress.
Cannot copy because PLC is running.
There is an error in the file system.
The number of registerable programs was exceeded.
The storage capacity was exceeded.
The data is protected.
The file name is too long.
(Longer than 256 characters)
Another input/output function is being executed via the
network.
There is already a file in the PC.
The directory was not found.
The file was not found.
Opening failed when reading files on PC.
Opening failed when writing files on PC.
An error occurred when reading files from PC.
An error occurred when writing files to PC.
The designated drive was not found in the PC.
Another input/output function is being executed via the
network.
The file is a parameter file, etc., and cannot be deleted.
The directory does not exist or was not designated.
The file was not found.
The file name format is illegal.
There is an error in the file system.
The data is protected.
Cannot delete because PLC is running.
Another input/output function is being executed via the
network.
A file that does not exist on the PC was required to be
deleted.
The designated directory is not in the PC.
The designated file does not exist.
The designated drive was not found in the PC.
The directory was not found.
The file was not found.
The directory could not be opened.
Calling of the file information failed.
The drive does not exist.