2. Screen Operation of A985GOT
Item
The initialization method designated by the auxiliary axis parameter #120
ABS Type (ABSOLUTE POSITION DETECTION PARAMETER) is
displayed in the column to the right of the item.
(Display details of the initialization method)
Dog type
Initial Stopper type : Stopper method
Initial Origin type
The status at initialization is displayed in the column below the item.
(Display details of the initialization status)
MR-J2-CT status
ABSOLUTE POSITION
LOSS
EXECUTING ABSOLUTE
POSITION INITIALIZATION
ON
STOPPER
EXECUTING REFERENCE
POINT SETTING ON
ZERO POINT RETURN
ABSOLUTE POSITION
ESTABLISHMENT
Explanation of display details
Completion
Illegality
Pressing
Press Rel.
Ret.Ref.P.
Origin type
Zero-P.Ret
search engine
2.7 Diagnosis
Display details
: Dog-type method
: Origin point alignment method
ABSOLUTE VALUE DETECTION PARAMETER
Stopper method
Illegality
Pressing
Press Rel.
Ret.Ref.P
: This is displayed when the absolute position of the
stopper, origin point alignment, or dog-type method is
established.
For the stopper and origin point alignment methods,
this shows that the grid has been reached, and the
initialization has been completed.
: This is displayed when the absolute position has
been lost in the stopper, origin point alignment, or
dog-type method.
: This is displayed during absolute position initialization
when the zero point is being initialized by the stopper
method.
This status continues until the stopper is reached.
: This status is entered once the stopper has been
reached, or when a fixed time has elapsed and the
current limit has been reached.
: This shows the status after the stopper, from the time
the stopper is released to the time immediately
before the axis reaches the grid after moving in the
opposite direction.
For the origin point alignment method, this indicates
the status when the tool is moving in the origin point
direction set in parameter #120 ABS Type to a time
just before the grid is reached.
: When the zero point is initialized by the origin point
alignment method, this indicates the status when the
tool is moving to the machine basic point from the
time during absolute position initialization, until the
origin point is designated.
: This shows that the tool has returned to the refernce
point by a dog-type method initialization.
I - 219
Origin point
Dog-type method
alignment method
Illegality
Illegality
Origin type
Origin return
Zero-P.Ret
Completion
Completion