Mitsubishi Electric i-MTR2-G02-M0 Data Book

Mitsubishi Electric i-MTR2-G02-M0 Data Book

11-16 kw

Advertisement

Data Book
I-MTR2-G02-M0_0521_EN
Elca Engine ver.
i-MTR2-G02-M0
11-16 kW
FULL INVERTER direct expansion air conditioners. Ideal for metrological rooms and
laboratories, combined with remote air-cooled condenser.
(The photo of the unit is indicative and may vary depending on the model)
HERMETIC BLCD INVERTER
COMPRESSORS
AIR DELIVERY FROM THE
BOTTOM OR FROM THE TOP
PLUG FANS WITH EC
ELECTRIC MOTOR
MODULATING
POST-HEATING COIL
INSERT HERE
YOUR CONTACT
DETAILS

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric i-MTR2-G02-M0

  • Page 1 Data Book I-MTR2-G02-M0_0521_EN Elca Engine ver. i-MTR2-G02-M0 11-16 kW FULL INVERTER direct expansion air conditioners. Ideal for metrological rooms and laboratories, combined with remote air-cooled condenser. (The photo of the unit is indicative and may vary depending on the model)
  • Page 2 ELCAdoc 19/05/2021 INDEX Data Book i-MTR2-G02-M0_0521_EN i-MTR2-G02-M0 1. CERTIFICATIONS 2. PRODUCT DESCRIPTION 2.1 GENERAL CHARACTERISTICS 2.2 INSTALLATION 2.3 PRODUCT FEATURES AND BENEFITS 2.4 F-GAS DIRECTIVE 2.5 MODEL IDENTIFICATION 2.6 TRANSPORT AND STORAGE TEMPERATURE 3. WORKING LIMITS 4. COMPONENTS OF THE UNIT 4.1 MAIN COMPONENTS...
  • Page 3 ELCAdoc 19/05/2021 INDEX Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: 383 – NUMBERED WIRINGS + UK REQUESTS OPTIONAL ACCESSORIES: 4181 – MODBUS PROTOCOL SERIAL CARD OPTIONAL ACCESSORIES: 4182 – LON PROTOCOL SERIAL CARD OPTIONAL ACCESSORIES: 4184 – BACNET MS/TP RS485 SERIAL CARD OPTIONAL ACCESSORIES: 4185 –...
  • Page 4 Liability disclaimer The present publication is drawn up by of information only and does not constitute an offer binding upon Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. has compiled the content of this publication to the best of its knowledge.
  • Page 5: Declaration Of Conformity

    ELCAdoc 19/05/2021 CERTIFICATIOS Data Book i-MTR2-G02-M0_0521_EN Company certifications ISO 9001 CERTIFICATION Quality Management System ISO 14001 CERTIFICATION Environmental Management System BS OHSAS 18001 CERTIFICATION Occupational Health and Safety Management System Product certifications by country CE MARKING CCC – CQC DECLARATION CERTIFICATION OF CONFORMITY (People’s Republic...
  • Page 6: Product Description

    ELCAdoc 19/05/2021 2. PRODUCT DESCRIPTION Data Book i-MTR2-G02-M0_0521_EN 2.1. GENERAL CHARACTERISTICS FULL INVERTER air conditioners ideal for metrological rooms and laboratories. • Direct expansion, air cooled • Prepared for coupling to remote air-cooled condenser • BLDC inverter compressors • Plug fans with EC electric motor •...
  • Page 7: Product Characteristics

    Single refrigerant circuit 2.4. F-GAS DIRECTIVE The units highlighted in this publication contain <HFC R410A [GWP 2088]> fluorinated greenhouse gases. 2.5. MODEL IDENTIFICATION Air conditioners for IT Cooling Model i-MTR2-G02-M0 U 018 E2 i-MTR2 Series R410A refrigerant Target market Air discharge...
  • Page 8: Working Limits

    ELCAdoc 19/05/2021 3. WORKING LIMITS Data Book i-MTR2-G02-M0_0521_EN Relative humidity - % Temperature with Dry bulb - °C AREA “A”. Operating area of the unit ROOM AIR CONDITIONS Room air temperature: 16°C Minimum temperature with dry bulb 24°C Maximum temperature with dry bulb Room air humidity: 40% RH Minimum relative humidity 70% RH Maximum relative humidity...
  • Page 9: Components Of The Unit

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 4. COMPONENTS OF THE UNIT Data Book i-MTR2-G02-M0_0521_EN 4.1. MAIN COMPONENTS FRAMEWORK • Frame in extruded aluminium, hot-coated with epoxy powder. Colour RAL 9005; • Base and frame in galvanized steel with epoxy powder coating. Colore RAL 7016. The internal frame is equipped with gaskets for the panels.
  • Page 10: Cooling Section

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 4. COMPONENTS OF THE UNIT Data Book i-MTR2-G02-M0_0521_EN • Impeller in corrosion-resistant composite material. • Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The microprocessor control sends a signal to change the revolutions of the motor.
  • Page 11: Electrical Panel

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 4. COMPONENTS OF THE UNIT Data Book i-MTR2-G02-M0_0521_EN • 0-10V proportional signal to command the condensing control system of the remote air-cooled condenser. • Modulating motorized diverter valve for control of post-heating coil. ELECTRICAL PANEL In accordance with EN60204-1 norms, suitable for indoor installation, complete with: •...
  • Page 12 ELCAdoc 19/05/2021 UNIT DESCRIPTION 4. COMPONENTS OF THE UNIT Data Book i-MTR2-G02-M0_0521_EN PASSWORD Level 1: On request of the End User. Allowing to reach USER menu Level 2: Asks to Service: Allowing to reach SERVICE menu Level 3: Asks to Service: Allowing to reach FACTORY menu No passwords request to enter: UNIT, SETPOINT, IN/OUT, CLOCK, HISTORY menu UNIT 2...
  • Page 13: Standard Equipment

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 4. COMPONENTS OF THE UNIT Data Book i-MTR2-G02-M0_0521_EN LAN NETWORK The LAN is part of the control software and it is possible to connect up to 15 units. This type of connection allows to control the units in coherent way, moreover the units can be controlled and managed from a shared remote terminal.
  • Page 14: Limit Values

    ELCAdoc 19/05/2021 4. COMPONENTS OF THE UNIT Data Book i-MTR2-G02-M0_0521_EN HUMIDIFIER VAP 5KG/H Modulating steam humidifier with immersed electrodes fitted with safety and running accessories. The optional includes the control board. The optional is factory installed and requires only water filling connection. Humidifier water charge and discharge pipes are not supplied.
  • Page 15: Hydraulic Connection

    ELCAdoc 19/05/2021 4. COMPONENTS OF THE UNIT Data Book i-MTR2-G02-M0_0521_EN • WARNING: • Use only with drinking water. • There is no reliable relationship between hardness and water conductivity • Do not treat water with softeners! This could cause corrosion of the electrodes or the formation of foam, leading to potential operating problems or failures.
  • Page 16 ELCAdoc 19/05/2021 5. SERIES GR-Z REMOTE AIR CONDENSERS Data Book i-MTR2-G02-M0_0521_EN Remote air condensers for matching to air conditioners for IT Cooling. They are designed to offer a high degree of application flexibility. The air flow is horizontal, from coil to fan. The series has an independent power supply from the indoor unit.
  • Page 17: Technical Data

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 6. TECHNICAL DATA Data Book i-MTR2-G02-M0_0521_EN MODEL    018   SIZE POWER SUPPLY V/Ph/Hz  400/3+N/50     400/3+N/50   COOLING CAPACITY (1) 100% 80% 60% 40% 30% 100% 80% 60% 40% 30% Total 11.10 8.88 6.66 4.44 3.34 15.80 12.64 9.48 6.32 4.74 Sensible 11.10 8.88 6.66 4.44 3.34 14.55 12.19 9.48 6.32 4.74 SHR (2)
  • Page 18: Refrigerant Charge

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 6. TECHNICAL DATA Data Book i-MTR2-G02-M0_0521_EN (1) Gross value in cooling only configuration. Characteristics referred to incoming air 24 °C-50% RH; condensing temperature 45 °C; EXP = 20Pa. (2) Gross sensible capacity in cooling only, reference conditions as in point 1. SHR = Sensible cooling capacity / Total cooling capacity.
  • Page 19 ELCAdoc 19/05/2021 UNIT DESCRIPTION 6. TECHNICAL DATA Data Book i-MTR2-G02-M0_0521_EN DIAGRAM OF REFRIGERANT CIRCUIT Description GAS DELIVERY LIQUID RETURN REMOTE CONDENSER PLUG FAN EVAPORATING COIL DEHYDRATOR FILTER LIQUID FLOW SIGHT GLASS COMPRESSOR HOT GAS POST-HEATING COIL LIQUID RECEIVER OIL HEATER OIL SEPARATOR PRESSURE SENSOR SP.H...
  • Page 20 ELCAdoc 19/05/2021 UNIT DESCRIPTION 6. TECHNICAL DATA Data Book i-MTR2-G02-M0_0521_EN RECOMMENDED COOLING LINES Diameters of cooling lines recommended for connection to MEHITS S.p.A. air conditioners and referred to the "EQUIVALENT LENGTH". Please always refer to the "INSTALLATION DIAGRAM" to select all the necessary components correctly. Check the need to use pressure relief devices (safety valves) where not already provided for in Directive 2014/68/EU.
  • Page 21: Installation Diagram

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 6. TECHNICAL DATA Data Book i-MTR2-G02-M0_0521_EN INSTALLATION DIAGRAM Apply the diagram to each refrigerant circuit of the unit. Difference in height between the units as an abso- lute value. Maximum equivalent length of the connection pipes: 100 m LEGEND 1.
  • Page 22: Acoustic Data

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 7. ACOUSTIC DATA Data Book i-MTR2-G02-M0_0521_EN Acoustic data of the standard unit working at full load. WARNING: In a closed room the noise produced by a sound source reaches the listener in two different ways: • Directly •...
  • Page 23: Electrical Data

    ELCAdoc 19/05/2021 8. ELECTRICAL DATA Data Book i-MTR2-G02-M0_0521_EN Electrical data of the system at full load working conditions. MODEL POWER SUPPLY V/ph/Hz 400/3+N/50 400/3+N/50 MAXIMUM CURRENT INPUT (FLA) 20.7 20.7 WARNING: The electric data indicated refer only to the indoor unit. Optional accessory electric data are included within the dedicated chapters and must be added.
  • Page 24 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN Front intake + bottom panel. Containment panel for soundproofing of the base of P121 the OVER unit Bottom intake + solid panels. Solid front panels for OVER units. The accessory P122 draws air from the bottom of the unit.
  • Page 25 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN Plenum + ePM2.5 50% filter. Plenum with high efficiency air filter (according to ISO P017 EN 16890). Not compatible with P084 ePM10 50% air filter. Plenum + ePM1 50% filter. Plenum with high efficiency air filter (according to ISO EN P018 16890).
  • Page 26 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: P121 - FRONT INTAKE + BOT- TOM PANEL Available for OVER unit. The accessory is not compatible with the “P122 Bottom intake + solid panels” for OVER units. The accessory is designed to soundproof the base of the unit in those installations where the unit is placed directly on certain floors (raised floors, wooden floors, etc.).
  • Page 27 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: P171 - AC AXIAL MCH -45°C AIR KIT (GR-Z A B 50) P171 - AC AXIAL MCH -45°C AIR KIT (GR-Z A B 50) The accessory is available only for air conditioners combined with remote air-cooled condensers with axial fans with AC electric motors: •...
  • Page 28 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: 4181 - MODBUS PROTOCOL SERIAL CARD The card is factory installed. Consult the Interface Manual for all technical information OPTIONAL ACCESSORIES: 4182 - LON PROTOCOL SERIAL CARD The card is factory installed. The manufacturer will supply the serial card and .NXE file and a .XIF files necessary for LonWorks technicians to configure the network.
  • Page 29 ELCAdoc 19/05/2021 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN A351 ACCESSORIES - GRAPHIC DISPLAY 132x64 pixel backlit standard graphic display with 6 physical buttons for navigating the menus. Alarm presence with red light. ALARM Push for alarm description. In case of more alarms scroll by UP / DOWN. Menu list, scrolled by UP/DOWN: Unit;...
  • Page 30 ELCAdoc 19/05/2021 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: A352 - NO DISPLAY The unit is supplied without display and adjustment is only possible with the KipLink accessory OPTIONAL ACCESSORIES: A35B - "EVOLUTION TOUCH" GRAPHIC DISPLAY 7” Touch-Screen graphic display with 16.7 million colours for the management and monitoring of operating and alarm states.
  • Page 31 ELCAdoc 19/05/2021 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: P151 - LOWERED DISPLAY FOR UNDER For units installed above the delivery plenum. The display/keyboard on the front panel of the machine is installed lowered by about 50cm to facilitate consultation and use. OPTIONAL ACCESSORIES: B912 - REMOTE KEYBOARD K200 Kit consisting of a diverter and an additional standard graphic display prepared for wall mounting.
  • Page 32: Storing Data

    ELCAdoc 19/05/2021 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN STORING DATA The system can store some data on a 1GB MicroSD card to be installed on the device. The data can be used for Service diagnostics. The card is not provided. KIPLINK NETWORK It is possible to set up mixed networks consisting of several KIPLink devices (10 maximum), to display information from different devices (called Client...
  • Page 33: Mounting Kit

    ELCAdoc 19/05/2021 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN A521 - FIRE DETECTOR The device in supplied in mounting kit. The fire detector has been designed to identify temperatures at which fires may start. When the temperature exceeds the set threshold or when there is a rapid variation in temperature, the relay is activated to signal an alarm.
  • Page 34 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: P071/P072/P073/P074 - REMOTE T/RH PROBE P071 / P072 / P073 / P074: REMOTE T/RH PROBES In addition to the on-board temperature probes, the unit’s control can manage up to 4 remote T/RH probes (optional), to measure the return and the delivery air temperature in different positions.
  • Page 35 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: P113 - DUAL SUPPLY KIT OPTIONAL ACCESSORIES: P114 - DUAL SUPPLY KIT + OPTIONAL The motorised changeover switches automatically manage changeover under load between two three-phase power supplies, or manually for emergency operations.
  • Page 36 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: A381 - CONDENSATE DISCHARGE PUMP A plastic case contains the vertical type pump, the water tank with float plus safety switch and hydraulic and electric connection. A 10-metre crush-resistant spiral drain pipe is provided with the pump. The optional has to be installed as shown in the documentation delivered together with the unit.
  • Page 37: Operating Data

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN CONDENSATE DRAIN PUMP (Sizes in millimetres) OPERATING DATA Total length of drain pipe (internal Ø of 10 mm) Head 5 m 10 m 20 m 30 m WATER FLOW RATE...
  • Page 38 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: P084 - ePM 50% AIR FILTERS The air filters with ePM 50% efficiency (according to ISO EN 16890) replace the standard ones. The filters generate a higher than standard pressure drop. The filters are made of glass microfibre and are disposable.
  • Page 39: Examples Of Installation

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN VERSION (1) U / O SIZE Weight (2) 1. U = Under, delivery air flow down / O = Over, delivery air flow up 2. Value to be added to the total weight of the unit EXAMPLES OF INSTALLATION Damper Damper...
  • Page 40 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: P011 - VACUUM PLENUM OPTIONAL ACCESSORIES: P012 - CL.A1 VACUUM PLENUM OPTIONAL ACCESSORIES: P031 - VACUUM INTAKE PLENUM OPTIONAL ACCESSORIES: P032 - CL.A1 VACUUM INTAKE PLENUM OPTIONAL ACCESSORIES: P013 - PLENUM + 3 GRILLES OPTIONAL ACCESSORIES: P014 - CL.A1 PLENUM + 3 GRILLES OPTIONAL ACCESSORIES: P015 - SILENT PLENUM OPTIONAL ACCESSORIES: P016 - SILENT PLENUM + 1 GRILLE...
  • Page 41 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN P011 / P012 OVER P031 / P032 OVER P011 / P012 UNDER P031 / P032 UNDER VERSION (1) U / O SIZE Weight (2) Weight of CL.0 or "A1" (EN 13501-1) (2) kg 1.
  • Page 42 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN P015: SILENT PLENUM The plenum must be installed on air delivery. The plenum has sound absorbers for noise reduction. Remove the frontal panels for inspection. P015 OVER P015 UNDER VERSION (1) U / O SIZE Weight (2)
  • Page 43 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN P016: SILENT PLENUM + 1 GRILLE The plenum must be installed on air delivery. The plenum distributes air directly from the front into the environment and reduces the noise of air delivery The plenum is supplied with a grille with double row of adjustable fins and sound absorbers on front side.
  • Page 44: Pressure Drop

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN P017 / P018 / P019: PLENUM + FILTER The plenum must be installed on air delivery. The accessory is not compatible with "P084 ePM10 50% air filter". The plenum is supplied with high efficiency rigid filters.
  • Page 45 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: P041 - FLOOR STAND H 255-350MM OPTIONAL ACCESSORIES: P042 - FLOOR STAND H 355-450MM OPTIONAL ACCESSORIES: P043 - FLOOR STAND H 400-510MM The accessory is supplied in a mounting kit. It is not possible to install the floor stand together with the plenums under the unit.
  • Page 46 ELCAdoc 19/05/2021 UNIT DESCRIPTION 9. OPTIONAL ACCESSORIES Data Book i-MTR2-G02-M0_0521_EN OPTIONAL ACCESSORIES: A272 – CL.0 or A1 (EN13501-1) INSULATION The accessory is designed FOR THE SUPPLY OF ONLY PANELS WITH FIRE REACTION IN CLASS “0” OR “A1 (EN 13501-1)”; it also allows for soundproofing of the air conditioner. The pressure level reduction of the unit is about 2 dB(A).
  • Page 47: Unit Drawings

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 10. UNIT DRAWINGS Data Book i-MTR2-G02-M0_0521_EN UNIT DRAWINGS - Dimensions in mm - UNDER E2...
  • Page 48 ELCAdoc 19/05/2021 UNIT DESCRIPTION 10. UNIT DRAWINGS Data Book i-MTR2-G02-M0_0521_EN UNIT DRAWINGS - Dimensions in mm - OVER E2...
  • Page 49 ELCAdoc 19/05/2021 UNIT DESCRIPTION 11. HOLE IN THE RAISED FLOOR FOR DOWNFLOW VERSION Data Book i-MTR2-G02-M0_0521_EN HOLE IN THE RAISED FLOOR FOR DOWNFLOW VERSION HOLE IN THE RAISED FLOOR WITHOUT FLOOR STAND Foresee a hole in the floor with the following dimensions: SIZE HOLE IN THE RAISED FLOOR WITH FLOOR STAND (OPTION) Foresee a hole in the floor with the following dimensions:...
  • Page 50 ELCAdoc 19/05/2021 UNIT DESCRIPTION 12. EXAMPLES OF CALCULATION OF THE SOUND EMISSION OF UNITS Data Book i-MTR2-G02-M0_0521_EN UNDER UNIT WITH DUCTING ON INTAKE Canal Lp A = Design value on front of Under Lp B = Design value on delivery of Under Lp C = Design value on intake of Under Points B and C do not influence point A UNDER UNIT WITH PLENUM ON DELIVERY...
  • Page 51 ELCAdoc 19/05/2021 UNIT DESCRIPTION 12. EXAMPLES OF CALCULATION OF THE SOUND EMISSION OF UNITS Data Book i-MTR2-G02-M0_0521_EN UNDER UNIT WITH PLENUM ON DELIVERY Lp A = Design value on intake of Over Lp B = Design value on delivery of Over – attenuation of plenum Lp A+B = 10 log10 (10 OVER UNIT WITH PLENUM ON INTAKE AND DUCTED DELIVERY...
  • Page 52: Shipping Weight

    ELCAdoc 19/05/2021 UNIT DESCRIPTION 13. INFORMATION ON SHIPPING Data Book i-MTR2-G02-M0_0521_EN 13.1. PACKING DIMENSIONS Values referred to basic unit. The presence of some accessories increases the weight of the unit. The units are shrink-wrapped on a pallet for shipping. On request, the unit can be packed on a pallet, shrink-wrapped and in a wooden crate. STANDARD OPTIONAL 9973: DIMENSIONS DIMENSIONS OF PACK...
  • Page 53 ELCAdoc 19/05/2021 UNIT DESCRIPTION 13. INFORMATION ON SHIPPING Data Book i-MTR2-G02-M0_0521_EN 13.3. DIMENSIONS OF PACK OF ACCESSORIES AND SHIPPING WEIGHT P011 - VACUUM PLENUM P012 - CL.A1 VACUUM PLENUM P031 - VACUUM INTAKE PLENUM P032 - CL.A1 VACUUM INTAKE PLENUM P013 - PLENUM + 3 GRILLES P014 - CL.A1 PLENUM + 3 GRILLES P015 - SILENT PLENUM...
  • Page 54 ELCAdoc 19/05/2021 UNIT DESCRIPTION 13. INFORMATION ON SHIPPING Data Book i-MTR2-G02-M0_0521_EN P034: FREE-COOLING INTAKE PLENUM The plenums are shipped on a pallet and shrink-wrapped. Size DIMENSIONS SHIPPING WEIGHT P034 - "U" freecooling intake plenum P034 - "O" freecooling intake plenum "O"...
  • Page 55 INSERT HERE YOUR CONTACT DETAILS...

Table of Contents