Error No.
E86
E87
E88
E91
E110
E111
E112
E113
E114
E115
E117
E165
E190
E191
E200
Downloaded from
ManualsNet.com
7.9 Operation Messages on Setting Display Unit
Error message
×
INPUT DATA ERR
×
NOT EDIT PROG.
×
CAN'T ADD
BLOCK
×
MODE ERROR
(PBK)
ATA NOT READY
FILE DUPLICATE
×
ATA I/F ERROR
×
MEMORY OVER
×
CAN'T ERASE
FILE NOT FOUND
×
DIR NOT FOUND
AUX RUNNING
×
FORE EDITING
×
NOT COM.
SEARCH
×
ADJUST ERROR
search engine
7. List of Alarms
• When inputting the tool offset data‚ the data format was not
correct‚ so that block could not be input.
If the input key is pressed again in the input screen‚ the input
will continue from the next block.
• When data is read from parameter tape, its format is incorrect.
• Playback edit was executed for a fixed cycle subprogram.
Playback edit of a fixed cycle subprogram is not possible.
• Playback edit cannot be executed unless the block being
edited with playback is displayed to the end (EOB) on the left
side of the machining program display area. Press the cursor
key‚ and display the whole block to the end. Then‚ input the
data.
• G90 was set when "PLAYBACK G90" was off.
• G91 was set when "PLAYBACK G90" was on.
• ATA not mounted error when that appears when ATA Card
screen is opened
Mount the ATA card.
• The name of the file to be output was found in the ATA card.
• New file name to be renamed already exists.
• The designated file is damaged or the ATA card is damaged.
Designate another file or replace the ATA card.
• The ATA card capacity was filled when outputting to the ATA
card.
Delete files from the ATA card, or use another ATA card and
output the data again.
• A directory containing subdirectories or files was required to be
deleted.
Delete the file and all subdirectories before deleting the
directory.
• The file to be input, compared, deleted or renamed was not
found in the ATA card.
Designate a file saved in the ATA card.
• The set directory was not found on the disk.
Check whether an intermediate directory was designated when
designating an absolute path.
• The keys other than Function/Menu/Previous page/Next page
were pressed in Auxiliary monitor screen during auxiliary axis
operation.
• An attempt was made to perform background search for the
program that is in foreground search status. (Word editing)
• Operation search was attempted in the tape mode.
• The hardware status can't be read correctly‚ so automatic
adjustment was not possible.
• Check the remote l/O unit.
• A Z55 RIO NOT CONNECT error occurred.
• Adjust manually.
• Unit defect (replace unit)