Error No.
E201
E301
E302
E311
E312
E313
E314
E315
E316
E317
E318
E319
Downloaded from
ManualsNet.com
7.9 Operation Messages on Setting Display Unit
Error message
×
UNIT NOT EQUIP
×
CONNECT
ERROR
×
LOGIN ERROR
×
DOWNLOAD ERR
×
UPLOAD ERROR
×
NO FILE
×
FILE DUPLICATE
×
FILE WRITE ERR
×
FILE READ ERR
×
MEMORY OVER
×
OVER FLOW ERR
×
DIRECTORY ERR
search engine
7. List of Alarms
• The analog output unit is not mounted.
• Confirm the remote l/O unit.
• Prepare a unit having analog output.
• Check the connection (power and signal wires)
• Unit defect (replace unit)
• The socket connection failed during Ethernet communication.
• If the host address is illegal or the port No. is incorrect, set
correctly.
• Log in failed during Ethernet communication.
• Check the user name and password.
• Reading of a file on the host side failed during Ethernet
communication.
• Writing of a file on the host side failed during Ethernet
communication.
• The file designated with the host reception (host → IC)
operation was not found on the host side during Ethernet
communication.
• The file designated with the host transmission (IC → host)
operation was not found in the IC card during Ethernet
communication.
• The file name to be registered with the host reception (host →
IC) operation was found in the IC card during Ethernet
communication.
• The file name to be registered with the host transmission (IC →
host) operation was found in the host during Ethernet
communication.
• Writing to the IC card failed during Ethernet communication.
• Reading of an IC cared file failed during Ethernet
communication.
• The IC card memory is full.
• The NC memory is full.
• There are too many files in the host directory.
• Movement of the directory failed.
IV - 65