Mitsubishi Electric MELDAS C6 Instruction Manual page 472

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

Error No.
002C
002D
003B
0045
0046
0047
0049
L13 DN MESSAGE ERR.
Error No.
0002
0008
0009
Downloaded from
ManualsNet.com
Details
When receiving a split poling response, the
received split data No. differed from the one
available.
When receiving a split poling response, the
middle data or final data was received
before receiving the first split data.
The same station No. (MAC ID) was
detected two or more times in the
parameters.
O.Addr in the parameters exceeds 255.
I.Addr in the parameters exceeds 255.
An illegal connection type was designated.
The expected packet rate value is smaller
than the production inhibit time value.
Error No.
Details
The resources required for executing the
required service could not be used.
The requested service is not mounted or is
not defined for this object class or instance.
Invalid attribute data was detected.
search engine
7. List of Alarms
7.8 Communication Error
Error detected while executing message
communication
IV - 56
Remedy
Generally check the state of the
network and slave, and confirm that the
terminator is not disconnected, etc.
Generally check the state of the
network and slave, and confirm that the
terminator is not disconnected, etc.
There are two or more slaves with the
same station No. in the parameters.
Correct the station numbers.
A slave with the same station No. as the
local station No. was found in the
parameters.
O.Addr to 255 or less.
I.Addr to 255 or less.
Confirm that the connection type value
is correct.
Set the expected packet rate value
higher than the production inhibit time
value.
Remedy
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.
Check that the designated MAC ID,
class ID, instance ID and attribute ID
are correct.
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.
Check that the designated MAC ID,
class ID, instance ID and attribute ID
are correct.
Referring to the slave manual, check
the conditions for the slave to notify this
error, and remedy accordingly.