(3) Remote I/O unit setting switches
A lever type switch (DS1) and rotary switch (CS) are provided at the front center of the remote I/O
unit.
The DX100 has one each of these switches, and the DX110/120 has two each of these switches.
Set the two levers of all DS1 switches to "OFF: left side".
CS1 can be set between "0" and "7". Refer to the following table and set. Note that the output
(D0) of the PCB on the right of the DX110/120, looking from the front, is a 16-point output.
Make sure that the CS setting No. is different from the other CS setting Nos.
Remote I/O unit CS setting
The device used by the PLC is determined by the setting of the rotary switch for setting the No. of
channels.
Rotary
switch No.
The values shown in parentheses are the device range when mounted to the right side of the unit.
(4) Servo drive unit setting switch
A rotary switch for setting the axis No. is located in the window at the top front of the servo drive
unit. Refer to the following table and set the axis No.
Downloaded from
ManualsNet.com
2. Startup and Adjustment Procedures
2.2 Setting the Various Switches
Device No. read in
RIO-M
RIO-M/S
0
X00~X1F
X100~X11F
1
X20~X3F
X120~X13F
2
X40~X5F
X140~X15F
3
X60~X7F
X160~X17F
4
X80~X9F
X180~X19F
5
XA0~XBF
X1A0~X1BF
6
XC0~XDF
X1C0~X1DF YC0~YDF (YCF) Y1C0~Y1DF (Y1CF)
7
XE0~XFF
X1E0~X1FF
Rotary
Axis No.
switch No.
0
1st axis
1
2nd axis
2
3rd axis
3
4th axis
4
5th axis
5
6th axis
6
7th axis
Non-used axis
F
selection
search engine
Output device No.
RIO-M
RIO-M/S
Y00~Y1F (Y0F)
Y100~Y11F (Y10F)
Y20~Y3F (Y2F)
Y120~Y13F (Y12F)
Y40~Y5F (Y4F)
Y140~Y15F (Y14F)
Y60~Y7F (Y6F)
Y160~Y17F (Y16F)
Y80~Y9F (Y8F)
Y180~Y19F (Y18F)
YA0~YBF (YAF)
Y1A0~Y1BF (Y1AF)
YE0~YFF (YEF)
Y1E0~Y1FF (Y1EF)
III - 6
Analog
output (AO)
The rotary
switches
correspond to
the file
registers
R100 to R103
in order of
small
numbers.