4.2 Jog Feed Mode

The jog feed mode enables the machine to be moved consecutively at the feedrate set by using the
MANUAL FEED RATE switch manually. The jog feed mode is started by using the FEED AXIS
SELECT switch.
See Section 5 for the MANUAL FEED RATE switch.
Operation procedure
Using the MODE SELECT switch,
select the jog mode.
Using the MANUAL FEED RATE
switch, set the feedrate.
The feedrate unit is the travel distance
(mm) per minute.
To move the controlled axis, turn on
the FEED AXIS SELECT switch. The
controlled axis is moved while the
switch is turned on.
When the switch is turned off, the
controlled axis stops with deceleration.
(Note 1) When the MANUAL OVERRIDE switch on the operation panel is turned on, the override
Downloaded from
ManualsNet.com
value set by using the FEED RATE OVERRIDE switch takes precedence over the
feedrate set by using the MANUAL FEED RATE switch.
search engine
4. Operation Mode
4.2 Jog Feed Mode
MDI
HANDLE
INCRE-
MENTAL
+X
-X
II - 8
MODE SELECT
MEMORY
RAPID
TRAVERSE
JOG
REFERENCE
POINT RETURN
MANUAL FEEDRATE
100
72.0
140.0
52.0
200.0
37.0
270.0
27.0
370.0
20.0
520.0
14.0
720.0
10.0
1000.0
7.2
1400.0
6.2
2000.0
3.7
2700.0
2.7
3700.0
2.0
5200.0
1.4
7200.0
1.0
10000.0
0
14000.0
mm/min
FEED AXIS SELECT
+4
+Y
+Z
-Y
-Z
-4