Tool Wear And Tool Length Data Setting Mode (Incremental/Absolute) - Mitsubishi Electric MELDAS C6 Instruction Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

(Refer to "2.3 (II). Tool Offset
(M system)" for M system.

2.3.1.3 Tool Wear and Tool Length Data Setting Mode (incremental/absolute)

Whether tool offset data is set as an absolute value or as an incremental value is designated on the
TOOL TIP OFFSET or TOOL DATA screen.
(Example) Incremental/absolute value setting
(1) Change over to the incremental setting mode
Set I in # ( ), then press the INPUT key.
(2) Change over to the absolute value setting mode
Set A in # ( ), then press the INPUT key.
(Note) The mode is held even if the screen is changed or the power is turned OFF.
Downloaded from
ManualsNet.com
2. Screen Operation of A985GOT
2.3 (I). Tool Offset (L system)
Display
#2 X
-100.000
# ( I) X (
) Z (
)
# ( A) X (
) Z (
)
search engine
Setting
• Incremental value setting
# (2) ( -
0.1)
• Absolute value setting
# (2) ( - 100.1)
"INC." is highlighted, and the mode becomes the
incremental value setting mode.
"ABS." is highlighted, and the mode becomes the
absolute value setting mode.
I - 49
Display
#2 X-100.100
#2 X-100.100