No Mac-Address-Table Aging-Time - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

The parameter has the following meaning:
Parameter
seconds
Result
The value of the aging of a dynamically learned entry is configured.
Further notes
You can reset the setting to the default with the no mac-address-table aging-time
command.
You display the setting with the show mac-address-table aging-time command.
10.3.2.2

no mac-address-table aging-time

Description
With this command, you reset the value for the aging of a dynamically learned entry in the
MAC address list to the default value.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no mac-address-table aging-time
Result
The value of the aging of a dynamically learned entry is reset to the default value.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Life of the entry in seconds
Load control
10.3 Dynamic MAC aging
Range of values / note
15 ... 630
Default: 300
Enter the period of time in seconds
in steps of 15.
When you input the Aging Time,
note that the WBM rounds to cor‐
rect values. If you enter a value
that cannot be divided by 15, the
value is automatically rounded
down.