The parameter has the following meaning:
Parameter
ip address
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
The IP address is removed.
Further notes
You enable the DHCP Relay Agent with the service dhcp-relay command.
You create the IP address with the ip dhcp server command.
You display the IP addresses with the show dhcp server command.
7.4.2.3

ip dhcp relay circuit-id option

Description
The Circuit ID is a sub option of the "DHCP Relay Information" option. The Circuit ID contains
information about the origin of the DHCP packet.
With this command, you specify the information contained in the Circuit ID.
The Circuit ID is encoded in the DHCP packet if the "DHCP relay information" option is enabled.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip dhcp relay circuit-id option [router-index] [vlanid] [recv-port]
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
IP address of the DHCP server
Network protocols
7.4 DHCP Relay
Range of values / note
Enter the IP address to be deleted.
311