Diagnostics
12.1 Event and fault handling
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
power [{L1|L2}]
The parameters have the following meaning:
Parameter
L1
L2
If you do not select any parameters from the parameter list, the default value "L1 and L2" is
used.
Result
The setting for monitoring the power supplies is configured.
Further notes
You can display the current setting with the show events faults config command.
You disable the function with the no power command.
12.1.8.9

no power

Description
With this command, you disable the monitoring of the power supplies.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no power [{L1|L2}}
562
Description
Monitoring of power supply 1
Monitoring of power supply 2
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06