Unicast-Block; No Unicast-Block - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Configuration
3.1 System
The parameters have the following meaning:
Parameter
10
100
Result
The transmission speed of the interface is configured.
3.1.10.17

unicast-block

Description
With this command, you enable the blocking of unknown unicast frames on an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
unicast-block
Result
Unicast frames are blocked.
Further notes
You disable the blocking of unicast frames with the no unicast-block command.
You display the status of this function with show unicast-block config.
3.1.10.18

no unicast-block

Description
With this command, you disable the blocking of unknown unicast frames on an interface.
88
Description
Transmission speed 10 Mbps
Transmission speed 100 Mbps
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface