Diagnostics
12.1 Event and fault handling
Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
● Message if there is cold or warm restart
● Message when there is a status change on a physical interface
● Message if there is an incorrect login
● Message when there is aRemote Monitoring alarm (RMON alarm)
● Message when there is a status change in the power supply
● Message when there is a status change in the redundancy manager (RM)
● Message when there is a status change on a standby connection
● Message when there is a status change in the error monitoring
● Message when there is a change in the spanning tree
● Message when there is a status change of the VRRP routers
● Message if there is a status change in the detection of network loops
● Message on status change of OSPF routers
● Message when there is a status change in the diagnostics data
● Message on status change of Link Check
● Message when an error was detected in the CLI script file:
These messages can be processed by the clients in different ways:
● Entry in the logbook of the device
● Sending the message to the Syslog server
● Sending an e-mail
● Sending an SNMP trap
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
event config
faultstate-change|
556
{cold-warmstart|linkchange|authentication-failure|
rmon-alarm|power-change|rm-state-change|standby-state-change|
stp-change|vrrp-state-change|loopd-state-change|ospf-state-
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06