Result
The e-mail name of the sender is configured.
Further notes
You reset the e-mail name of the sender with the no sender mail-address.
You display the setting with the show events sender email command.
7.6.2.4

no sender mail-address

Description
With this command, you reset the e-mail name of the sender.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
no sender mail-address
Result
The e-mail name of the sender is reset.
Further notes
You configure the e-mail name of the sender with the sender mail-address.
You display the setting with the show events sender email command.
7.6.2.5

send test mail

Description
With this command, you send an e-mail according to the currently configured SMTP settings.
Requirement
You are in the EVENTS configuration mode.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Network protocols
7.6 SMTP client