Syntax
Call up the command with the following parameters:
option <option-code> { <ip-address-list> | int-ip }
The parameters have the following meaning:
Parameter
option-
code
ip-adress-
list
int-ip
Result
The DHCP option is created.
Further notes
You display the setting with the show ip dhcp-server pools command.
You disable the IPv4 address band with the no pool-enable command.
You delete the DHCP option with the no option command.
You configure the DHCP options 12, 66 and 67 with the option value-string command.
You configure the interface with the set interface command.
7.3.3.4

option value-string

Description
With this command you configure DHCP options 12, 66 and 67 that contain a string as DHCP
parameter. The DHCP options 66 and 67 are created automatically when the IPv4 address
band is created.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Code of the DHCP option
IPv4 address or IPv4 address list
Uses IPv4 address of the interface that is
assigned to the IPv4 address band.
Network protocols
7.3 DHCP server
Range of values / note
● 3 - Default gateway
● 6 - DNS server
● DHCP option 3 (default gateway):
Enter the DHCP parameter as an IPv4
address, e.g. 192.168.100.2.
● DHCP option 6 (name server):
Enter the DHCP parameter as an IPv4
address, e.g. 192.168.100.2. You can
specify up to three IPv4 addresses
separated by commas.
Only with DHCP option 3