No Ip Address - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Network protocols
7.2 DHCP client
The command prompt is as follows:
cli(config-vlan-$$$)#
Syntax
Call the command without parameter assignment:
ip address dhcp
Result
The IP address is assigned using DHCP.
Further notes
You delete the setting with the no ip address command.
7.2.3.2

no ip address

Description
With this command, you delete the assignment of an IP address and disable DHCP.
Requirement
You are in the Interface Configuration mode of VLAN.
The command prompt is as follows:
cli(config-if-vlan-$$$)#
Syntax
Call up the command with the following parameters:
no ip address [{ <ucast_addr> | dhcp }]
The parameter has the following meaning:
Parameter
ucast-addr
dhcp
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
286
Description
Value for an IPv4 unicast address
Specify this parameter if you want to
disable the DHCP function explicitly.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
Enter a valid IPv4 unicast address.
-
Configuration Manual, 07/2017, C79000-G8976-C361-06

Hide quick links:

Advertisement

Table of Contents
loading